Application of Multilayer Coatings in the Waste Incinerator ZEVO Pilsen

Abstract This study evaluates the surface protection of a waste-to-energy boiler wall using the Eutronic Arc Spray Gun 4 HFH. The test involved coating a 3.2 m² section of the boiler membrane wall with four materials: BTW 58 (FeCr-based), METCO 8294 (NiCrMo alloy), TAFALOY 71T (Inconel 625), and Metcoloy 4 (FeCr steel). Before spraying, the surface was grit-blasted to SA 3 finish with a roughness of 75–100 μm. Coatings were applied both with and without a Metco 8450 bonding layer. Additionally, two high-temperature ceramic coatings—Fireside and Tubearmor—were tested. The wear tests were conducted on-site in the boiler's third pass. After one year of exposure, samples were evaluated for condition, wear, and scale formation. BTW 58 and TAFALOY 71T, particularly when combined with Fireside ceramic coating, provided the most effective protection.

Authors

Institutions

Publication Details

Journal
Thermal spray
Published
2025-05-01
DOI
https://doi.org/10.31399/asm.cp.itsc2025p0268
Primary Topic
Catalysis and Hydrodesulfurization Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Multilayer Coatings in the Waste Incinerator ZEVO Pilsen

Jakub Antoš, Marek Vostřák, Pavel Veselý, J. Ray Frank et al.
Thermal spray
Catalysis and Hydrodesulfurization Studies
article

Application of Multilayer Coatings in the Waste Incinerator ZEVO Pilsen

Jakub Antoš, Marek Vostřák, Pavel Veselý, J. Ray Frank, Jan Hruška, Zdeněk Česánek, Tomáš Taranda
article en

Abstract

Abstract This study evaluates the surface protection of a waste-to-energy boiler wall using the Eutronic Arc Spray Gun 4 HFH. The test involved coating a 3.2 m² section of the boiler membrane wall with four materials: BTW 58 (FeCr-based), METCO 8294 (NiCrMo alloy), TAFALOY 71T (Inconel 625), and Metcoloy 4 (FeCr steel). Before spraying, the surface was grit-blasted to SA 3 finish with a roughness of 75–100 μm. Coatings were applied both with and without a Metco 8450 bonding layer. Additionally, two high-temperature ceramic coatings—Fireside and Tubearmor—were tested. The wear tests were conducted on-site in the boiler's third pass. After one year of exposure, samples were evaluated for condition, wear, and scale formation. BTW 58 and TAFALOY 71T, particularly when combined with Fireside ceramic coating, provided the most effective protection.

Thermal sprayVol. 85045
Research and Testing Institute Plzen (Czechia) (CZ)
Openalex Percentile: Top 91%
Catalysis and Hydrodesulfurization Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines