Technical Study of Arresters in the 20 KV Distribution Network at PT. PLN RAYON TANDES

Arrester is a device in an electrical system that will protect electrical equipment caused by lightning. Study the characteristics of lightning rods so you can see their performance in protecting transformers during lightning surges. Pay attention to the factors that will influence the voltage and surge current, the distance of the lightning protection, the slope of the incident wave, the speed of the surge wave, and the basic insulation level. The level of failure to protect against lightning occurs because of the basic insulation level of the device and the location of the lightning protection device, in calculating the voltage value. The nominal lightning rod is installed continuously on the lightning rod without affecting its operating characteristics. The rated voltage value of the lightning rod is 22 kV, the rated voltage of the 20 kV lightning rod is 24 kV in the distribution network and the protection factor value is the lightning protection level. After making the protection level value 95.7 kV, the protection factor value with the TID of the 125 kV transformer is determined. The protection factor value is 23.44, the protection factor value is 20% higher than the tolerance factor.

Authors

Publication Details

Journal
Jurnal Teknik Elektro
Published
2025-04-26
DOI
https://doi.org/10.31000/jte.v8i2.13864
Primary Topic
Industrial Automation and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technical Study of Arresters in the 20 KV Distribution Network at PT. PLN RAYON TANDES

Arif Setiawan, Yusuf Alamsyah Putra, Izzah Aulia Wardah
Jurnal Teknik Elektro
Industrial Automation and Control Systems
article

Technical Study of Arresters in the 20 KV Distribution Network at PT. PLN RAYON TANDES

Arif Setiawan, Yusuf Alamsyah Putra, Izzah Aulia Wardah
article en

Abstract

Arrester is a device in an electrical system that will protect electrical equipment caused by lightning. Study the characteristics of lightning rods so you can see their performance in protecting transformers during lightning surges. Pay attention to the factors that will influence the voltage and surge current, the distance of the lightning protection, the slope of the incident wave, the speed of the surge wave, and the basic insulation level. The level of failure to protect against lightning occurs because of the basic insulation level of the device and the location of the lightning protection device, in calculating the voltage value. The nominal lightning rod is installed continuously on the lightning rod without affecting its operating characteristics. The rated voltage value of the lightning rod is 22 kV, the rated voltage of the 20 kV lightning rod is 24 kV in the distribution network and the protection factor value is the lightning protection level. After making the protection level value 95.7 kV, the protection factor value with the TID of the 125 kV transformer is determined. The protection factor value is 23.44, the protection factor value is 20% higher than the tolerance factor.

Jurnal Teknik ElektroVol. 8(2)
Openalex Percentile: Top 90%
Industrial Automation and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Technical Study of Arresters in the 20 KV Distribution Network at PT. PLN RAYON TANDES — Arif Setiawan, Yusuf Alamsyah Putra, et al. · Jurnal Teknik Elektro (2025) | TGRS Research Map | TGRS