Systematic Comparison of Commercial Uranyl‐Alternative Stains for Negative‐ and Positive‐Staining Transmission Electron Microscopy of Organic Specimens

Negative- and positive-staining transmission electron microscopy (ns/psTEM) is a cornerstone of research and diagnostics, enabling nanometer-resolution analysis of organic specimens from nanoparticles to cells without requiring costly cryo-equipment. For nearly 70 years, uranyl salts like uranyl acetate (UA) have been the gold-standard ns/psTEM-stains. However, mounting safety concerns due to their high toxicity and radioactivity have led to stricter regulations and expensive licensing requirements. Consequently, there is an urgent global demand for safer, more sustainable stains that deliver uranyl-comparable, high-quality ns/psTEM. Here, the commercially available stain-alternatives UranyLess, UAR, UA-Zero, PTA, STAIN 77, Nano-W, NanoVan, and lead citrate are systematically assessed against UA. The stains are evaluated regarding their contrast, resolution, stain-distribution, and ease-of-use in ns/psTEM across a diverse sample set, including polymethylmethacrylate-nanoplastics, phosphatidylcholine-liposomes, Influenza-A viruses, globular ferritin, fibrillar pyruvate kinase amyloids, and human lung-carcinoma cell-sections. It is shown that for this variety of samples, a ready-to-use uranyl-alternative is commercially available with comparable or even superior ns/psTEM-performance to UA using an efficient staining-protocol. Furthermore, the GUIDE4U tool is developed for the fast identification of the appropriate uranyl-replacements for each sample of interest, saving ns/psTEM-users time and costs while ensuring excellent staining results for ultrastructural analysis, thereby further catalyzing the use of safer stains.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2025-04-29
DOI
https://doi.org/10.1002/adhm.202404870
Citations
5
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
3.31

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Systematic Comparison of Commercial Uranyl‐Alternative Stains for Negative‐ and Positive‐Staining Transmission Electron Microscopy of Organic Specimens

Gea Cereghetti, Davide Bottone, Vera M. Kissling, Peter Wick et al.
5 citations
Advanced Healthcare Materials
Electron and X-Ray Spectroscopy Techniques
3.31
article

Systematic Comparison of Commercial Uranyl‐Alternative Stains for Negative‐ and Positive‐Staining Transmission Electron Microscopy of Organic Specimens

Gea Cereghetti, Davide Bottone, Vera M. Kissling, Peter Wick, Stephanie Eitner
article en
5 citations

Abstract

Negative- and positive-staining transmission electron microscopy (ns/psTEM) is a cornerstone of research and diagnostics, enabling nanometer-resolution analysis of organic specimens from nanoparticles to cells without requiring costly cryo-equipment. For nearly 70 years, uranyl salts like uranyl acetate (UA) have been the gold-standard ns/psTEM-stains. However, mounting safety concerns due to their high toxicity and radioactivity have led to stricter regulations and expensive licensing requirements. Consequently, there is an urgent global demand for safer, more sustainable stains that deliver uranyl-comparable, high-quality ns/psTEM. Here, the commercially available stain-alternatives UranyLess, UAR, UA-Zero, PTA, STAIN 77, Nano-W, NanoVan, and lead citrate are systematically assessed against UA. The stains are evaluated regarding their contrast, resolution, stain-distribution, and ease-of-use in ns/psTEM across a diverse sample set, including polymethylmethacrylate-nanoplastics, phosphatidylcholine-liposomes, Influenza-A viruses, globular ferritin, fibrillar pyruvate kinase amyloids, and human lung-carcinoma cell-sections. It is shown that for this variety of samples, a ready-to-use uranyl-alternative is commercially available with comparable or even superior ns/psTEM-performance to UA using an efficient staining-protocol. Furthermore, the GUIDE4U tool is developed for the fast identification of the appropriate uranyl-replacements for each sample of interest, saving ns/psTEM-users time and costs while ensuring excellent staining results for ultrastructural analysis, thereby further catalyzing the use of safer stains.

Advanced Healthcare MaterialsVol. 14(16)
University of Cambridge (GB), Swiss Federal Laboratories for Materials Science and Technology (CH)
UK Research and Innovation, European Commission, Eidgenössische Technische Hochschule Zürich, HORIZON EUROPE Framework Programme, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 8%
Electron and X-Ray Spectroscopy Techniques
3.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.