HARMONIC REDUCTION FOR SINGLE-PHASE UNINTERRUPTIBLE POWER SUPPLY INVERTER

Numerous control strategies for Uninterruptible Power Supply (UPS) inverters have been proposed, with the primary objectives of voltage tracking, stability, and maintaining a perfect sinusoidal waveform even under nonlinear loads, varying loads, and the presence of disturbances. A proposed method is two Multiple Loop Control (MLC) with an outer voltage control loop tracking the reference voltage and an inner current control loop to reduce the steady-state error of the load voltage, reduce harmonics in the main circuit current, and improve system efficiency. The controller's robustness based on the Lyapunov function is proven by sudden load changes and variations in the reference voltage along with the presence of noise. The fundamental principles of Lyapunov's theorem are applied to the state equations to calculate the switching function for generating Pulse Width Modulation (PWM) to reduce harmonics in UPS. Simulations and experiments were conducted using MATLAB-Simulink. Results demonstrated that the UPS output voltage and current can track the reference values from low to high, regardless of sudden load changes or reference voltage variations, and in the presence of noise. The total harmonic distortion (THD) of the current was significantly reduced to 0.04%, meeting the IEEE-519 standard.

Authors

Institutions

Publication Details

Journal
Journal of Science and Technology - IUH
Published
2025-04-29
DOI
https://doi.org/10.46242/jstiuh.v74i2.5298
Citations
1
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HARMONIC REDUCTION FOR SINGLE-PHASE UNINTERRUPTIBLE POWER SUPPLY INVERTER

Nguyễn Vinh Quan, Tao Hai, Pham Tran Bich Thuan
1 citations
Journal of Science and Technology - IUH
Multilevel Inverters and Converters
0.73
article

HARMONIC REDUCTION FOR SINGLE-PHASE UNINTERRUPTIBLE POWER SUPPLY INVERTER

Nguyễn Vinh Quan, Tao Hai, Pham Tran Bich Thuan
article en
1 citations

Abstract

Numerous control strategies for Uninterruptible Power Supply (UPS) inverters have been proposed, with the primary objectives of voltage tracking, stability, and maintaining a perfect sinusoidal waveform even under nonlinear loads, varying loads, and the presence of disturbances. A proposed method is two Multiple Loop Control (MLC) with an outer voltage control loop tracking the reference voltage and an inner current control loop to reduce the steady-state error of the load voltage, reduce harmonics in the main circuit current, and improve system efficiency. The controller's robustness based on the Lyapunov function is proven by sudden load changes and variations in the reference voltage along with the presence of noise. The fundamental principles of Lyapunov's theorem are applied to the state equations to calculate the switching function for generating Pulse Width Modulation (PWM) to reduce harmonics in UPS. Simulations and experiments were conducted using MATLAB-Simulink. Results demonstrated that the UPS output voltage and current can track the reference values from low to high, regardless of sudden load changes or reference voltage variations, and in the presence of noise. The total harmonic distortion (THD) of the current was significantly reduced to 0.04%, meeting the IEEE-519 standard.

Journal of Science and Technology - IUHVol. 74(2)
Industrial University of Ho Chi Minh City (VN)
Openalex Percentile: Top 29%
Multilevel Inverters and Converters
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.