Detection of Cross-Line Successive Faults in Non-Effective Neutral Grounding Distribution Networks

In a non-effectively grounded neutral point distribution network, prolonged feeder operation reduces the insulation level, thereby increasing the likelihood of single-phase grounding faults that can generate over-voltages and eventually lead to successive two-point grounding faults. Existing detection methods for single-phase grounding faults fail to identify the second grounding fault in such scenarios. This paper derives the steady-state analytical expressions for the electrical quantities during faults and examines the characteristic differences at various stages of successive grounding faults under different fault phase sequences. Based on these distinctive features, the paper proposes a detection method for successive cross-line grounding faults with varying fault phases. The effectiveness of the proposed algorithm is verified through both simulation and field data.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-04-29
DOI
https://doi.org/10.3390/en18092269
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Cross-Line Successive Faults in Non-Effective Neutral Grounding Distribution Networks

Mingming Xu, Zhi Li, Ruirui Xie, Yuxuan Jin et al.
Energies
Smart Grid Security and Resilience
article

Detection of Cross-Line Successive Faults in Non-Effective Neutral Grounding Distribution Networks

Mingming Xu, Zhi Li, Ruirui Xie, Yuxuan Jin, Xuan Dong, Bin Wang
article en

Abstract

In a non-effectively grounded neutral point distribution network, prolonged feeder operation reduces the insulation level, thereby increasing the likelihood of single-phase grounding faults that can generate over-voltages and eventually lead to successive two-point grounding faults. Existing detection methods for single-phase grounding faults fail to identify the second grounding fault in such scenarios. This paper derives the steady-state analytical expressions for the electrical quantities during faults and examines the characteristic differences at various stages of successive grounding faults under different fault phase sequences. Based on these distinctive features, the paper proposes a detection method for successive cross-line grounding faults with varying fault phases. The effectiveness of the proposed algorithm is verified through both simulation and field data.

EnergiesVol. 18(9)
Inner Mongolia Electric Power (China) (CN), Tsinghua University (CN)
State Grid Corporation of China
Openalex Percentile: Top 90%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Cross-Line Successive Faults in Non-Effective Neutral Grounding Distribution Networks — Mingming Xu, Zhi Li, et al. · Energies (2025) | TGRS Research Map | TGRS