The clinical evaluation of the effectiveness of various minimally invasive methods in the treatment of central serous chorioretinopathy

Aim: clinical evaluation of the effectiveness of various lasers in treating acute and chronic central serous chorioretinopathy.Methods. The study involved 50 patients (53 eyes) with central serous chorioretinopathy (CSCR): 32 (60.4%) with the acute form and 18 (39.6%) with the chronic form. Patients were divided into three groups based on treatment and the leakage point's (LP) location. Group 1; 19 patients (19 eyes) received focal laser coagulation. Group 2 included 24 patients (24 eyes) who underwent subthreshold micropulse laser treatment (SMLT) for retinal neuroepithelial detachment. Group 3; 7 patients (10 eyes) with chronic disease underwent focal coagulation combined with SMLT, with LP confirmed via fluorescein angiography (FA). The observation lasted 6 months.Results. At the 4-week follow-up, Group 1's best corrected visual acuity (BCVA) improved by 60.2% to 0.75±0.01, with central retinal thickness (CRT) decreasing by 72.8% to 257.2±13.1 µm (p<0.05). Group 2 experienced a 30% BCVA improvement to 0.5±0.02, and a 32.1% CRT reduction to 266.6±10.3 µm (p<0.05). Group 3 showed a 26.5% BCVA increase to 0.35±0.01, with CRT decreasing by 27.3% to 280.6±14.5 µm (p<0.05).Conclusions. When the leakage point (LP) is located in the subfoveal region, in cases of the chronic form of the disease with large-area diffuse hyperfluorescence, in situations where the filtration point is not detected by fluorescein angiography (FA), and in cases of disease recurrence, subthreshold micropulse laser treatment, the use of subthreshold micropulse mode laser devices with a yellow wavelength (577 nm) is considered a safe and effective therapeutic method.

Authors

Institutions

Publication Details

Journal
Oftalmologicheskii Zhurnal
Published
2025-04-21
DOI
https://doi.org/10.31288/oftalmolzh202523441
Primary Topic
Retinal and Optic Conditions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The clinical evaluation of the effectiveness of various minimally invasive methods in the treatment of central serous chorioretinopathy

М.Х. Каримова, A. F. Yusupov, A. Sh. Aktamov, Sh.A. Djamalova et al.
Oftalmologicheskii Zhurnal
Retinal and Optic Conditions
article

The clinical evaluation of the effectiveness of various minimally invasive methods in the treatment of central serous chorioretinopathy

М.Х. Каримова, A. F. Yusupov, A. Sh. Aktamov, Sh.A. Djamalova, D. CH. Ibodullaeva
article en

Abstract

Aim: clinical evaluation of the effectiveness of various lasers in treating acute and chronic central serous chorioretinopathy.Methods. The study involved 50 patients (53 eyes) with central serous chorioretinopathy (CSCR): 32 (60.4%) with the acute form and 18 (39.6%) with the chronic form. Patients were divided into three groups based on treatment and the leakage point's (LP) location. Group 1; 19 patients (19 eyes) received focal laser coagulation. Group 2 included 24 patients (24 eyes) who underwent subthreshold micropulse laser treatment (SMLT) for retinal neuroepithelial detachment. Group 3; 7 patients (10 eyes) with chronic disease underwent focal coagulation combined with SMLT, with LP confirmed via fluorescein angiography (FA). The observation lasted 6 months.Results. At the 4-week follow-up, Group 1's best corrected visual acuity (BCVA) improved by 60.2% to 0.75±0.01, with central retinal thickness (CRT) decreasing by 72.8% to 257.2±13.1 µm (p<0.05). Group 2 experienced a 30% BCVA improvement to 0.5±0.02, and a 32.1% CRT reduction to 266.6±10.3 µm (p<0.05). Group 3 showed a 26.5% BCVA increase to 0.35±0.01, with CRT decreasing by 27.3% to 280.6±14.5 µm (p<0.05).Conclusions. When the leakage point (LP) is located in the subfoveal region, in cases of the chronic form of the disease with large-area diffuse hyperfluorescence, in situations where the filtration point is not detected by fluorescein angiography (FA), and in cases of disease recurrence, subthreshold micropulse laser treatment, the use of subthreshold micropulse mode laser devices with a yellow wavelength (577 nm) is considered a safe and effective therapeutic method.

Oftalmologicheskii ZhurnalVol. 115(2)
Kohat University of Science and Technology (PK), Republican Scientific and Practical Center of Neurology and Neurosurgery (BY)
Zero hunger
Openalex Percentile: Top 85%
Retinal and Optic Conditions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.