Preclinical Volume Retention of Fat Grafts Processed with REVOLVE™ Technology or Decantation Methods in Irradiated and Nonirradiated Wounds

<b>Background:</b> The processing of harvested fat for transplantation is critical to fat graft performance. In breast reconstruction, larger volumes of fat are being grafted and, in some clinical cases, are being implanted within radiated tissue. This preclinical animal study evaluated the effects of radiation on retention volume and fat graft quality after processing by decantation or REVOLVE™ technology (Allergan Aesthetics, an AbbVie Company), a filtration-based device that can process lipoaspirates and remove unwanted contaminants prior to grafting. <b>Methods:</b> Lipoaspirate was collected from human donors (<i>n</i> = 6), processed using either REVOLVE™ technology or decantation, and implanted (0.5 cc) into 60 athymic mice for 4 weeks with or without a single 35-Gy radiation dose 12 weeks prior. Volume composition, MRI, and weight-based volumetric assessment of grafted fat were performed and compared between radiated and non-radiated mice. <b>Results:</b> Volume composition analysis demonstrated significantly higher fat content and lower aqueous fluid with REVOLVE™ technology than with decantation, with minimal cellular debris and free oil. MRI-based and weight-based volume analysis demonstrated a significantly higher percent retention with REVOLVE™ technology than decantation in nonirradiated and irradiated sites, respectively. Pathology scoring showed a significant decrease in fibrosis within grafts processed with REVOLVE™ technology in nonirradiated sites. <b>Conclusions:</b> Results suggest that fat processed using REVOLVE™ technology provides better early volume retention and quality of fat grafts compared to decantation, both in healthy and radiation-treated surgical sites.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-04-30
DOI
https://doi.org/10.3390/jcm14093100
Primary Topic
Mesenchymal stem cell research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preclinical Volume Retention of Fat Grafts Processed with REVOLVE™ Technology or Decantation Methods in Irradiated and Nonirradiated Wounds

Graham M. Grogan, Patrick S. Cottler, Nimesh Kabaria, Chris A. Campbell et al.
Journal of Clinical Medicine
Mesenchymal stem cell research
article

Preclinical Volume Retention of Fat Grafts Processed with REVOLVE™ Technology or Decantation Methods in Irradiated and Nonirradiated Wounds

Graham M. Grogan, Patrick S. Cottler, Nimesh Kabaria, Chris A. Campbell, S Jean, Maryellen Gardocki-Sandor
article en

Abstract

<b>Background:</b> The processing of harvested fat for transplantation is critical to fat graft performance. In breast reconstruction, larger volumes of fat are being grafted and, in some clinical cases, are being implanted within radiated tissue. This preclinical animal study evaluated the effects of radiation on retention volume and fat graft quality after processing by decantation or REVOLVE™ technology (Allergan Aesthetics, an AbbVie Company), a filtration-based device that can process lipoaspirates and remove unwanted contaminants prior to grafting. <b>Methods:</b> Lipoaspirate was collected from human donors (<i>n</i> = 6), processed using either REVOLVE™ technology or decantation, and implanted (0.5 cc) into 60 athymic mice for 4 weeks with or without a single 35-Gy radiation dose 12 weeks prior. Volume composition, MRI, and weight-based volumetric assessment of grafted fat were performed and compared between radiated and non-radiated mice. <b>Results:</b> Volume composition analysis demonstrated significantly higher fat content and lower aqueous fluid with REVOLVE™ technology than with decantation, with minimal cellular debris and free oil. MRI-based and weight-based volume analysis demonstrated a significantly higher percent retention with REVOLVE™ technology than decantation in nonirradiated and irradiated sites, respectively. Pathology scoring showed a significant decrease in fibrosis within grafts processed with REVOLVE™ technology in nonirradiated sites. <b>Conclusions:</b> Results suggest that fat processed using REVOLVE™ technology provides better early volume retention and quality of fat grafts compared to decantation, both in healthy and radiation-treated surgical sites.

Journal of Clinical MedicineVol. 14(9)
AbbVie (United States) (US), Allergan (United States) (US), University of Virginia (US)
Openalex Percentile: Top 87%
Mesenchymal stem cell research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.