Feasibility of Photoplethysmography in Detecting Arterial Stiffness in Hypertension

Asymptomatic peripheral artery disease (PAD) poses a silent risk, potentially leading to severe conditions if undetected. Integrating new screening tools into routine general practitioner (GP) visits could enable early detection. This study investigates the feasibility of photoplethysmography (PPG) monitoring for assessing vascular health across different blood pressure (BP) conditions. Custom femoral artery phantoms representing healthy (0.82 MPa), intermediate (1.48 MPa), and atherosclerotic (2.06 MPa) vessels were tested under hypertensive, normotensive, and hypotensive conditions to evaluate PPG’s ability to distinguish between vascular states. Extracted features from the PPG signal, including amplitude, area under the curve (AUC), median upslope–downslope ratio, and median end datum difference, were analysed. Kruskal–Wallis tests revealed significant differences between healthy and unhealthy vessels across BP states, supporting PPG as a screening tool. The fiducial points from the second derivative of the photoplethysmography signal (SDPPG) were analysed. The ba ratio was most pronounced between healthy and unhealthy phantoms under hypertensive conditions (ranging from –2.13 to –2.06), suggesting a change in vascular wall distensibility. Under normotensive conditions, the difference in ba ratios between healthy and unhealthy phantoms was smaller (0.01), and no meaningful difference was observed under hypotensive conditions, suggesting the reduced sensitivity of this metric at lower perfusion pressures. Intermediate states were challenging to detect, particularly under hypotension, suggesting a need for further research. Nonetheless, this study highlights the promise of PPG monitoring in identifying vascular stiffness.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-04-29
DOI
https://doi.org/10.3390/photonics12050430
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of Photoplethysmography in Detecting Arterial Stiffness in Hypertension

James M. May, P. A. Kyriacou, Parmis Karimpour
Photonics
Non-Invasive Vital Sign Monitoring
article

Feasibility of Photoplethysmography in Detecting Arterial Stiffness in Hypertension

James M. May, P. A. Kyriacou, Parmis Karimpour
article en

Abstract

Asymptomatic peripheral artery disease (PAD) poses a silent risk, potentially leading to severe conditions if undetected. Integrating new screening tools into routine general practitioner (GP) visits could enable early detection. This study investigates the feasibility of photoplethysmography (PPG) monitoring for assessing vascular health across different blood pressure (BP) conditions. Custom femoral artery phantoms representing healthy (0.82 MPa), intermediate (1.48 MPa), and atherosclerotic (2.06 MPa) vessels were tested under hypertensive, normotensive, and hypotensive conditions to evaluate PPG’s ability to distinguish between vascular states. Extracted features from the PPG signal, including amplitude, area under the curve (AUC), median upslope–downslope ratio, and median end datum difference, were analysed. Kruskal–Wallis tests revealed significant differences between healthy and unhealthy vessels across BP states, supporting PPG as a screening tool. The fiducial points from the second derivative of the photoplethysmography signal (SDPPG) were analysed. The ba ratio was most pronounced between healthy and unhealthy phantoms under hypertensive conditions (ranging from –2.13 to –2.06), suggesting a change in vascular wall distensibility. Under normotensive conditions, the difference in ba ratios between healthy and unhealthy phantoms was smaller (0.01), and no meaningful difference was observed under hypotensive conditions, suggesting the reduced sensitivity of this metric at lower perfusion pressures. Intermediate states were challenging to detect, particularly under hypotension, suggesting a need for further research. Nonetheless, this study highlights the promise of PPG monitoring in identifying vascular stiffness.

PhotonicsVol. 12(5)
St George's, University of London (GB), City St George's, University of London (GB)
Openalex Percentile: Top 92%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines