Optical coherence tomography angiography integrating differential phase and intensity images for <i>in vivo</i> imaging of a mouse retina

Optical coherence tomography angiography (OCTA) suffers from more motion artifacts compared to optical coherence tomography, which are the primary source of image quality degradation in <i>in vivo</i> imaging. We propose an OCTA algorithm in this Letter that differs from motion compensation methods widely employed to reduce motion artifacts and effectively mitigates these artifacts. The algorithm integrates differential phase and intensity images based on the standard deviation of the flow signals. The performance of this algorithm is evaluated on mouse retina <i>in vivo</i> imaging. Compared to three conventional OCTA algorithms, the OCTA images obtained by the proposed algorithm exhibit fewer motion artifacts and less noise in tissue regions, with maximum improvements of 1.38 dB and 0.82 in signal-to-noise ratio and contrast-to-noise ratio (CNR), respectively, in the maximum projection of <i>en face</i> images.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-04-30
DOI
https://doi.org/10.1364/ol.557676
Citations
1
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical coherence tomography angiography integrating differential phase and intensity images for in vivo imaging of a mouse retina

Xiaoqi Lu, Hongtao Wei, Weiye Song, Xiang He et al.
1 citations
Optics Letters
Optical Coherence Tomography Applications
0.67
article

Optical coherence tomography angiography integrating differential phase and intensity images for in vivo imaging of a mouse retina

Xiaoqi Lu, Hongtao Wei, Weiye Song, Xiang He, Yi Wan, Yongjian Li, Fuwang Wu, Kaixuan Hu, Wei Yi
article en
1 citations

Abstract

Optical coherence tomography angiography (OCTA) suffers from more motion artifacts compared to optical coherence tomography, which are the primary source of image quality degradation in <i>in vivo</i> imaging. We propose an OCTA algorithm in this Letter that differs from motion compensation methods widely employed to reduce motion artifacts and effectively mitigates these artifacts. The algorithm integrates differential phase and intensity images based on the standard deviation of the flow signals. The performance of this algorithm is evaluated on mouse retina <i>in vivo</i> imaging. Compared to three conventional OCTA algorithms, the OCTA images obtained by the proposed algorithm exhibit fewer motion artifacts and less noise in tissue regions, with maximum improvements of 1.38 dB and 0.82 in signal-to-noise ratio and contrast-to-noise ratio (CNR), respectively, in the maximum projection of <i>en face</i> images.

Optics LettersVol. 50(13)
Shandong University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Key Technology Research and Development Program of Shandong
Openalex Percentile: Top 32%
Optical Coherence Tomography Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.