Frequency calibration method for improved precision and stability of direct laser absorption spectroscopy

Tunable diode laser absorption spectroscopy is widely used for detecting trace gases, as it combines good selectivity and sensitivity with noninvasive setups and fast response. Among the multiple implementation possibilities, direct absorption spectroscopy stands out, since it allows for straightforward determination of the number density. The frequency accuracy of the laser tuning is a fundamental limit to the precision of these setups, and in order to improve frequency calibration, a method utilizing variable frequency modulation is presented. It leverages the phase-sensitive behavior of mixing the light intensity signal and the modulation source to establish an absolute frequency reference of the absorption signal. The frequency modulation of laser diode sidebands in a range from 400 MHz to 1.1 GHz are used for frequency calibration without the use of external elements in the optical setup. These fixed frequency beacons are embedded in an algorithm that demonstrates improved performance of direct absorption spectroscopy using this method. The approach is implemented in a setup for molecular oxygen spectroscopy using a VCSEL laser near 394.3298 THz (760.7845 nm).

Authors

Publication Details

Journal
Optics Letters
Published
2025-04-30
DOI
https://doi.org/10.1364/ol.557982
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency calibration method for improved precision and stability of direct laser absorption spectroscopy

Michael Jakubowsky, Stefan Palzer, K. H. Wu
Optics Letters
Spectroscopy and Laser Applications
article

Frequency calibration method for improved precision and stability of direct laser absorption spectroscopy

Michael Jakubowsky, Stefan Palzer, K. H. Wu
article en

Abstract

Tunable diode laser absorption spectroscopy is widely used for detecting trace gases, as it combines good selectivity and sensitivity with noninvasive setups and fast response. Among the multiple implementation possibilities, direct absorption spectroscopy stands out, since it allows for straightforward determination of the number density. The frequency accuracy of the laser tuning is a fundamental limit to the precision of these setups, and in order to improve frequency calibration, a method utilizing variable frequency modulation is presented. It leverages the phase-sensitive behavior of mixing the light intensity signal and the modulation source to establish an absolute frequency reference of the absorption signal. The frequency modulation of laser diode sidebands in a range from 400 MHz to 1.1 GHz are used for frequency calibration without the use of external elements in the optical setup. These fixed frequency beacons are embedded in an algorithm that demonstrates improved performance of direct absorption spectroscopy using this method. The approach is implemented in a setup for molecular oxygen spectroscopy using a VCSEL laser near 394.3298 THz (760.7845 nm).

Optics LettersVol. 50(11)
Affordable and clean energy
Openalex Percentile: Top 92%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.