Evaluation of deliverable artificial intelligence-based automated volumetric arc radiation therapy planning for whole pelvic radiation in gynecologic cancer

This study aimed to develop a deep learning (DL)-based deliverable whole pelvic volumetric arc radiation therapy (VMAT) for patients with gynecologic cancer using a prototype DL-based automated planning support system, named RatoGuide, to evaluate its clinical validity. In our hospital, 110 patients with gynecologic cancer were registered. The prescribed dose was 50.4 Gy/28 fr. A DL-based three-dimensional dose prediction model was first trained by the dose distribution and structure data of whole pelvic VMAT (n = 100) created on the Monaco treatment planning system (TPS). The structure data of the test data (n = 10) were then input to RatoGuide, and RatoGuide predicted the dose distribution of the whole pelvic VMAT plan (PreDose). We established deliverable plans with Monaco and Eclipse TPS (DeliDose) based on PreDose and vendor-supplied optimization objectives. Medical physicists then manually developed plans (CliDose) for the test data. Finally, we evaluated and compared the dose distribution and dose constraints of PreDose, DeliDose, and CliDose. DeliDose, in both Eclipse and Monaco, was comparable to PreDose in most Dose constraints, planning target volume (PTV) coverage, and Dmax of the bladder, rectum, and bowel bag were better for DeliDose than for PreDose. Additionally, DeliDose demonstrated no significant difference from CliDose in most dose constraints. The blinded average scores of radiation oncologists for DeliDose and CliDose were 4.2 ± 0.4 and 4.3 ± 0.5, respectively, in Eclipse, and 4.0 ± 0.6 and 3.9 ± 0.5, respectively, in Monaco (5 is the max score and 3 is clinically acceptable). We indicated that RatoGuide can eliminate variations in plan quality between hospitals in whole pelvic VMAT irradiation and help develop VMAT plans in a short time.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-30
DOI
https://doi.org/10.1038/s41598-025-99717-y
Citations
3
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
5.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of deliverable artificial intelligence-based automated volumetric arc radiation therapy planning for whole pelvic radiation in gynecologic cancer

Keiichi Jingu, Rei Umezawa, Yoshiyuki Katsuta, Shohei Tanaka et al.
3 citations
Scientific Reports
Advanced Radiotherapy Techniques
5.65
article

Evaluation of deliverable artificial intelligence-based automated volumetric arc radiation therapy planning for whole pelvic radiation in gynecologic cancer

Keiichi Jingu, Rei Umezawa, Yoshiyuki Katsuta, Shohei Tanaka, Noriyuki Kadoya, Yuto Kimura, Kazuhiro Arai, T. Hoshino, Yushan Xiao, Kiyokazu Sato, Haruna Takahashi
article en
3 citations

Abstract

This study aimed to develop a deep learning (DL)-based deliverable whole pelvic volumetric arc radiation therapy (VMAT) for patients with gynecologic cancer using a prototype DL-based automated planning support system, named RatoGuide, to evaluate its clinical validity. In our hospital, 110 patients with gynecologic cancer were registered. The prescribed dose was 50.4 Gy/28 fr. A DL-based three-dimensional dose prediction model was first trained by the dose distribution and structure data of whole pelvic VMAT (n = 100) created on the Monaco treatment planning system (TPS). The structure data of the test data (n = 10) were then input to RatoGuide, and RatoGuide predicted the dose distribution of the whole pelvic VMAT plan (PreDose). We established deliverable plans with Monaco and Eclipse TPS (DeliDose) based on PreDose and vendor-supplied optimization objectives. Medical physicists then manually developed plans (CliDose) for the test data. Finally, we evaluated and compared the dose distribution and dose constraints of PreDose, DeliDose, and CliDose. DeliDose, in both Eclipse and Monaco, was comparable to PreDose in most Dose constraints, planning target volume (PTV) coverage, and Dmax of the bladder, rectum, and bowel bag were better for DeliDose than for PreDose. Additionally, DeliDose demonstrated no significant difference from CliDose in most dose constraints. The blinded average scores of radiation oncologists for DeliDose and CliDose were 4.2 ± 0.4 and 4.3 ± 0.5, respectively, in Eclipse, and 4.0 ± 0.6 and 3.9 ± 0.5, respectively, in Monaco (5 is the max score and 3 is clinically acceptable). We indicated that RatoGuide can eliminate variations in plan quality between hospitals in whole pelvic VMAT irradiation and help develop VMAT plans in a short time.

Scientific ReportsVol. 15(1)
Tohoku University (JP), Tohoku University Hospital (JP), Gunma Chuo Hospital (JP)
Openalex Percentile: Top 4%
Advanced Radiotherapy Techniques
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.