Research on AC voltage source measurement system based on Joseph quantum voltage

A measurement system for AC voltage source was designed based on AC/DC thermoelectric conversion technology By analyzing the error sources of the measurement system, a DC voltage self calibration scheme based on Joseph Quantum voltage was designed The DC voltage self calibration system uses differential sampling principle to directly trace the DC voltage source to the Josephson quantum voltage standard The polynomial least squares fitting curve algorithm is used to determine the calibration coefficient of the DC voltage source Through analysis, it is proven that the polynomial least squares fitting curve algorithm can reduce the uncertainty components introduced by linear fitting during the calibration process Through comparative experiments with test data from the China Institute of Metrology, the results showed that the device has high accuracy and stability characteristics

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1145/3719477.3719485
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on AC voltage source measurement system based on Joseph quantum voltage

Wenbo Yao, Yongxian Duan, Ailing Geng, Wei Jun Cen
Advanced Electrical Measurement Techniques
article

Research on AC voltage source measurement system based on Joseph quantum voltage

Wenbo Yao, Yongxian Duan, Ailing Geng, Wei Jun Cen
article en

Abstract

A measurement system for AC voltage source was designed based on AC/DC thermoelectric conversion technology By analyzing the error sources of the measurement system, a DC voltage self calibration scheme based on Joseph Quantum voltage was designed The DC voltage self calibration system uses differential sampling principle to directly trace the DC voltage source to the Josephson quantum voltage standard The polynomial least squares fitting curve algorithm is used to determine the calibration coefficient of the DC voltage source Through analysis, it is proven that the polynomial least squares fitting curve algorithm can reduce the uncertainty components introduced by linear fitting during the calibration process Through comparative experiments with test data from the China Institute of Metrology, the results showed that the device has high accuracy and stability characteristics

North China Electric Power University (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 72%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on AC voltage source measurement system based on Joseph quantum voltage — Wenbo Yao, Yongxian Duan, et al. · (2024) | TGRS Research Map | TGRS