Pilot study on the use of an off-the-shelf 3D-printed titanium acetabular rim extension implant for treating canine hip dysplasia

Hip dysplasia (HD) is one of the most prevalent orthopedic issues in dogs. Generic shelf implants are 3D-printed devices designed to address HD in dogs of varying sizes and hip laxity scores. This pilot study evaluated the feasibility and effectiveness of generic shelf implants in six dogs diagnosed with bilateral HD. Each dog underwent bilateral hip surgery in a single session followed by a 12-month monitoring period. Post-operative CT scans revealed increased femoral head coverage in all 12 hips, resulting in reversed hip laxity. However, implants exhibited positional deviations from optimal congruency for 5.1 ± 1.7 mm. Mild to moderate osteoarthritis (OA) progression was observed during the lead times and post-operatively. Although force plate analysis showed no significant changes, functional outcomes improved, as demonstrated by reduced owner questionnaire scores at 12 months post-surgery. Post-operative internal rotation and abduction angles were reduced compared to pre-operative values, suggesting potential impingement due to implant positioning. Complications were observed in one dog (two hips). Another dog died nine months post-surgery due to unrelated causes. Post-mortem histology and micro-CT analysis of these hip joints revealed localized cartilage depletion around the implant's rim extension area. However, no lameness or hip discomfort was reported by the owner before the dog's death. The generic shelf implant effectively enhances hip stability and alleviates pain-related behaviors by improving femoral head coverage. Suboptimal placement was associated with reduced range of motion and OA progression in this study. Refinements to the implant design and adjusting sizing protocols to better match acetabular morphology are necessary.

Authors

Institutions

Publication Details

Journal
Research in Veterinary Science
Published
2025-04-29
DOI
https://doi.org/10.1016/j.rvsc.2025.105668
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pilot study on the use of an off-the-shelf 3D-printed titanium acetabular rim extension implant for treating canine hip dysplasia

Björn P. Meij, Ralph J. B. Sakkers, Saber Amin Yavari, Joëll Magré et al.
Research in Veterinary Science
Veterinary Orthopedics and Neurology
article

Pilot study on the use of an off-the-shelf 3D-printed titanium acetabular rim extension implant for treating canine hip dysplasia

Björn P. Meij, Ralph J. B. Sakkers, Saber Amin Yavari, Joëll Magré, Koen Willemsen, Femke Verseijden, Amir Kamali, Marianna A. Tryfonidou, Harrie Weinans, Irin Kwananocha, Saskia Plomp, Bart C. H. van der Wal
article en

Abstract

Hip dysplasia (HD) is one of the most prevalent orthopedic issues in dogs. Generic shelf implants are 3D-printed devices designed to address HD in dogs of varying sizes and hip laxity scores. This pilot study evaluated the feasibility and effectiveness of generic shelf implants in six dogs diagnosed with bilateral HD. Each dog underwent bilateral hip surgery in a single session followed by a 12-month monitoring period. Post-operative CT scans revealed increased femoral head coverage in all 12 hips, resulting in reversed hip laxity. However, implants exhibited positional deviations from optimal congruency for 5.1 ± 1.7 mm. Mild to moderate osteoarthritis (OA) progression was observed during the lead times and post-operatively. Although force plate analysis showed no significant changes, functional outcomes improved, as demonstrated by reduced owner questionnaire scores at 12 months post-surgery. Post-operative internal rotation and abduction angles were reduced compared to pre-operative values, suggesting potential impingement due to implant positioning. Complications were observed in one dog (two hips). Another dog died nine months post-surgery due to unrelated causes. Post-mortem histology and micro-CT analysis of these hip joints revealed localized cartilage depletion around the implant's rim extension area. However, no lameness or hip discomfort was reported by the owner before the dog's death. The generic shelf implant effectively enhances hip stability and alleviates pain-related behaviors by improving femoral head coverage. Suboptimal placement was associated with reduced range of motion and OA progression in this study. Refinements to the implant design and adjusting sizing protocols to better match acetabular morphology are necessary.

Research in Veterinary ScienceVol. 191
Utrecht University (NL), Kasetsart University (TH), Heidelberg University (DE), University Hospital Heidelberg (DE), University Medical Center Utrecht (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Openalex Percentile: Top 90%
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.