Dynamic blood compatibility assessment of coronary stents using an innovative pneumatic blood pump to generate physiological flow rates in small sample chambers

According to ISO 10993-4, shear-dependent processes must be considered in the blood compatibility testing of cardiovascular implants, which demands controlled and physiological flow conditions in the test environment. For very small test objects such as coronary stents with a diameter below 5 mm, this is difficult to achieve, as previous test methods are either unable to represent the required flow velocities in small-lumen sample chambers, or can only do so under high pump shear stress, which in extreme cases can mask the effects of the tiny test objects. In this paper, we present a novel concept for dynamic in vitro models based on pneumatically generated blood flow (AirDrive technology), which can achieve flow rates and velocities up to 450 ml min<sup>-1</sup> or 930 mm s<sup>-1</sup>, respectively. This allows for hemocompatibility testing of coronary stents under physiologically high flow rates without generating major shear stress from the pump mechanism. In an initial feasibility study, single coronary stents with different surface finishes (polished/unpolished) were subjected to flow velocities of up to 560 mm s<sup>-1</sup> in a 3.2 mm diameter sample chamber. Blood samples were collected before and after perfusion, and haematological and coagulation markers were analysed. Unpolished stents elicited higher shear-induced blood responses than polished stents. This demonstrates that our experimental setup is highly sensitive and enables precise and robust investigation of blood compatibility under physiologically relevant flow conditions, even for the smallest objects under investigation. To show the superiority of this novel model in creating high flow rates while maintaining minimal blood damage, the AirDrive system was compared to the commonly used roller pump closed-loop system, with the former exhibiting significantly less blood damage. This further confirms that the AirDrive technology we present in this paper is of the highest value for developmental or regulatory testing of blood compatibility of small- and medium-sized test objects.

Authors

Institutions

Publication Details

Journal
Journal of Materials Science Materials in Medicine
Published
2025-04-29
DOI
https://doi.org/10.1007/s10856-025-06882-7
Citations
1
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic blood compatibility assessment of coronary stents using an innovative pneumatic blood pump to generate physiological flow rates in small sample chambers

Felix Pfisterer, Eitan Gross, Michael Kirschbaum, Anne-Sophie Hönicke et al.
1 citations
Journal of Materials Science Materials in Medicine
Mechanical Circulatory Support Devices
0.67
article

Dynamic blood compatibility assessment of coronary stents using an innovative pneumatic blood pump to generate physiological flow rates in small sample chambers

Felix Pfisterer, Eitan Gross, Michael Kirschbaum, Anne-Sophie Hönicke, Simon Beydoun
article en
1 citations

Abstract

According to ISO 10993-4, shear-dependent processes must be considered in the blood compatibility testing of cardiovascular implants, which demands controlled and physiological flow conditions in the test environment. For very small test objects such as coronary stents with a diameter below 5 mm, this is difficult to achieve, as previous test methods are either unable to represent the required flow velocities in small-lumen sample chambers, or can only do so under high pump shear stress, which in extreme cases can mask the effects of the tiny test objects. In this paper, we present a novel concept for dynamic in vitro models based on pneumatically generated blood flow (AirDrive technology), which can achieve flow rates and velocities up to 450 ml min<sup>-1</sup> or 930 mm s<sup>-1</sup>, respectively. This allows for hemocompatibility testing of coronary stents under physiologically high flow rates without generating major shear stress from the pump mechanism. In an initial feasibility study, single coronary stents with different surface finishes (polished/unpolished) were subjected to flow velocities of up to 560 mm s<sup>-1</sup> in a 3.2 mm diameter sample chamber. Blood samples were collected before and after perfusion, and haematological and coagulation markers were analysed. Unpolished stents elicited higher shear-induced blood responses than polished stents. This demonstrates that our experimental setup is highly sensitive and enables precise and robust investigation of blood compatibility under physiologically relevant flow conditions, even for the smallest objects under investigation. To show the superiority of this novel model in creating high flow rates while maintaining minimal blood damage, the AirDrive system was compared to the commonly used roller pump closed-loop system, with the former exhibiting significantly less blood damage. This further confirms that the AirDrive technology we present in this paper is of the highest value for developmental or regulatory testing of blood compatibility of small- and medium-sized test objects.

Journal of Materials Science Materials in MedicineVol. 36(1)
Fraunhofer Institute for Cell Therapy and Immunology (DE)
Fraunhofer-Institut für Zelltherapie und Immunologie
Openalex Percentile: Top 32%
Mechanical Circulatory Support Devices
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.