Modular Engineering of the DNAzyme-Based Electrochemiluminescence Biosensor with the Nitrogen and Sulfur Codoped Carbon Dots as Near-Infrared Emitters for MicroRNA detection

DNAzyme-based biosensors remain at the forefront of microRNA (miRNA) analysis efforts. In this work, an electrochemiluminescence (ECL) biosensor technology integrating miRNA-initiated DNAzyme with a near-infrared ECL emission system was designed to detect miRNA. The DNAzyme was designed through the rational reconstitution of Mg<sup>2+</sup>-specific 8-17 DNAzyme. We engineered the DNAzyme strand with incorporation of a blocker strand to inhibit the DNAzyme activity. The blocker strand formed a duplex structure that prohibited the hybridization of the DNAzyme strand with the one arm of the substrate strand, leading to the formation of an inactive DNAzyme structure. In the presence of target miRNA, the hybridization between the target miRNA and the blocker strand would induce the breakage of the duplex, followed by the formation of the active DNAzyme. Thus, the activity of the DNAzyme biosensors could be switched from the OFF state into the ON state. Moreover, the nitrogen and sulfur codoped near-infrared emission carbon dots (NIR NS-CDs) were used as neoteric ECL emitters, which not only possessed an NIR ECL emission to reduce the photochemical damage but also had a low excitation potential range to avoid the side reaction. Therefore, by combining the DNAzyme modular engineering strategy and NIR NS-CDs as neoteric ECL emitters, the constructed ECL biosensor could realize the ultrasensitive analysis of miRNA-155 with an identification limit of 58.5 aM. This DNAzyme-guided NIR ECL emission of the neoteric CD strategy provides a sensitive and reliable method for miRNA detection, and it has great potential in clinical diagnosis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-29
DOI
https://doi.org/10.1021/acs.analchem.5c00522
Citations
5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modular Engineering of the DNAzyme-Based Electrochemiluminescence Biosensor with the Nitrogen and Sulfur Codoped Carbon Dots as Near-Infrared Emitters for MicroRNA detection

Benting Xie, Hejun Gao, Yunwen Liao, Haonan He et al.
5 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
4.03
article

Modular Engineering of the DNAzyme-Based Electrochemiluminescence Biosensor with the Nitrogen and Sulfur Codoped Carbon Dots as Near-Infrared Emitters for MicroRNA detection

Benting Xie, Hejun Gao, Yunwen Liao, Haonan He, Hongquan Fu, Shuang Li, Juan Zhang
article en
5 citations

Abstract

DNAzyme-based biosensors remain at the forefront of microRNA (miRNA) analysis efforts. In this work, an electrochemiluminescence (ECL) biosensor technology integrating miRNA-initiated DNAzyme with a near-infrared ECL emission system was designed to detect miRNA. The DNAzyme was designed through the rational reconstitution of Mg<sup>2+</sup>-specific 8-17 DNAzyme. We engineered the DNAzyme strand with incorporation of a blocker strand to inhibit the DNAzyme activity. The blocker strand formed a duplex structure that prohibited the hybridization of the DNAzyme strand with the one arm of the substrate strand, leading to the formation of an inactive DNAzyme structure. In the presence of target miRNA, the hybridization between the target miRNA and the blocker strand would induce the breakage of the duplex, followed by the formation of the active DNAzyme. Thus, the activity of the DNAzyme biosensors could be switched from the OFF state into the ON state. Moreover, the nitrogen and sulfur codoped near-infrared emission carbon dots (NIR NS-CDs) were used as neoteric ECL emitters, which not only possessed an NIR ECL emission to reduce the photochemical damage but also had a low excitation potential range to avoid the side reaction. Therefore, by combining the DNAzyme modular engineering strategy and NIR NS-CDs as neoteric ECL emitters, the constructed ECL biosensor could realize the ultrasensitive analysis of miRNA-155 with an identification limit of 58.5 aM. This DNAzyme-guided NIR ECL emission of the neoteric CD strategy provides a sensitive and reliable method for miRNA detection, and it has great potential in clinical diagnosis.

Analytical ChemistryVol. 97(18)
China West Normal University (CN)
Openalex Percentile: Top 6%
Advanced biosensing and bioanalysis techniques
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.