Geriatric Type II Fractures of the Dens Axis: Biomechanical Superiority of a New Osteosynthesis Plate Compared to Common Anterior Screw Fixation

Study DesignBiomechanical Basic Research.ObjectivesType II Fractures of the dens axis (DFTII) are common fractures of the cervical spine in geriatric patients. A surgical approach is the anterior screw fixation (ASF). However, a disadvantage is the high post-operative rate of non-union. This study aimed to develop and biomechanically test an osteosynthesis plate (OSP) for the anterior treatment of DFTII in comparison to ASF.MethodsA novel OSP was developed and manufactured. The OSP was biomechanically tested in comparison to ASF in synthetic bone models and geriatric human cadaveric bone. An analysis of the bone microstructure of the human C2 vertebrae was performed utilizing high-resolution quantitative computed tomography to exclude differences in bone quality among the experimental groups. Biomechanical testing was performed by cyclic loading of compression and tensile forces until failure.ResultsIn the comparative biomechanical analysis of ASF and OSP in synthetic bone, significant differences were observed regarding the load to failure, favoring the OSP (<i>P</i> = 0.040). The comparative biomechanical analysis of ASF and OSP in the cadaveric specimens also revealed a significantly lower load to failure of the ASF (<i>P</i> = 0.046). The experimental groups did not show significant differences regarding age, sex or bone microstructure.ConclusionsThe current study demonstrated that the OSP is biomechanically superior to the ASF, indicating higher stability. This study provides the basis for an alternative anterior treatment option for DFTII.

Authors

Institutions

Publication Details

Journal
Global Spine Journal
Published
2025-04-29
DOI
https://doi.org/10.1177/21925682251338814
Citations
2
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geriatric Type II Fractures of the Dens Axis: Biomechanical Superiority of a New Osteosynthesis Plate Compared to Common Anterior Screw Fixation

Ali Bay, Benjamin Ondruschka, Simon von Kroge, Anna Lena Kammal et al.
2 citations
Global Spine Journal
Spinal Fractures and Fixation Techniques
4.01
article

Geriatric Type II Fractures of the Dens Axis: Biomechanical Superiority of a New Osteosynthesis Plate Compared to Common Anterior Screw Fixation

Ali Bay, Benjamin Ondruschka, Simon von Kroge, Anna Lena Kammal, Tim Rolvien, Lennart Viezens, Karl‐Heinz Frosch, Holger Kleinertz, L.G. Leonhardt, Michael Dirks, Matthias Münch, Malte Schroeder
article en
2 citations

Abstract

Study DesignBiomechanical Basic Research.ObjectivesType II Fractures of the dens axis (DFTII) are common fractures of the cervical spine in geriatric patients. A surgical approach is the anterior screw fixation (ASF). However, a disadvantage is the high post-operative rate of non-union. This study aimed to develop and biomechanically test an osteosynthesis plate (OSP) for the anterior treatment of DFTII in comparison to ASF.MethodsA novel OSP was developed and manufactured. The OSP was biomechanically tested in comparison to ASF in synthetic bone models and geriatric human cadaveric bone. An analysis of the bone microstructure of the human C2 vertebrae was performed utilizing high-resolution quantitative computed tomography to exclude differences in bone quality among the experimental groups. Biomechanical testing was performed by cyclic loading of compression and tensile forces until failure.ResultsIn the comparative biomechanical analysis of ASF and OSP in synthetic bone, significant differences were observed regarding the load to failure, favoring the OSP (<i>P</i> = 0.040). The comparative biomechanical analysis of ASF and OSP in the cadaveric specimens also revealed a significantly lower load to failure of the ASF (<i>P</i> = 0.046). The experimental groups did not show significant differences regarding age, sex or bone microstructure.ConclusionsThe current study demonstrated that the OSP is biomechanically superior to the ASF, indicating higher stability. This study provides the basis for an alternative anterior treatment option for DFTII.

Global Spine JournalVol. 16(1)
Universität Hamburg (DE), Sana Kliniken AG (DE), University Medical Center Hamburg-Eppendorf (DE), BG Klinikum Hamburg (DE)
Good health and well-being
Openalex Percentile: Top 8%
Spinal Fractures and Fixation Techniques
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.