Highly Sensitive and Diversified Electrochemiluminescence DNA Methylation Biosensing Platform Based on Self-Assembly of Nanotags

This work proposes a highly sensitive, simple, and reliable electrochemiluminescence (ECL) DNA methylation biosensing platform by employing DNA-functionalized magnetic beads (DNA-MBs) for target capture and nanotag self-assembly aggregation for signal amplification. The target methylated DNA was first captured on DNA-MBs through base pairing recognition, and then its methylation sites were recognized by antibody-5mC (Ab-5mC). Afterward, a pair of antibodies functionalized [Ru(byp)<sub>3</sub>]<sup>2+</sup>-doped silica nanoparticles (Ab<sub>2</sub>-Ru@SiO<sub>2</sub> and Ab<sub>3</sub>-Ru@SiO<sub>2</sub>) was layer-by-layer assembled on Ab-5mC for amplified signal transduction. The sensing beads could be transferred to screen-printed carbon electrodes (SPCEs) for ECL curve detection via photomultiplier tube or to gold-coated indium tin oxide (Au/ITO) arrays for high-throughput imaging detection. As the nanotag assembly layers increased from 1 to 3, the detection sensitivities of SPCE-based curve detection and Au/ITO-based imaging detection were enhanced 7-fold and 3-fold, achieving detection limits down to 0.8 pM and 0.9 fM, respectively. The nanotags showed good stability, with storage times of 300 days for Ru@SiO<sub>2</sub> and 60 days for Ab-Ru@SiO<sub>2</sub>, respectively. This method is universal and could be applied to detect different methylated DNAs by using their corresponding DNA-MBs. The proposed ECL biosensing platform possessed advantages of high sensitivity, good diversity, and practicality, showing potential for high-throughput DNA methylation detection in clinical diagnosis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-29
DOI
https://doi.org/10.1021/acs.analchem.5c00516
Citations
8
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
6.45

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive and Diversified Electrochemiluminescence DNA Methylation Biosensing Platform Based on Self-Assembly of Nanotags

Jie Wu, Huangxian Ju, Qian Yu, Yuan Chen et al.
8 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
6.45
article

Highly Sensitive and Diversified Electrochemiluminescence DNA Methylation Biosensing Platform Based on Self-Assembly of Nanotags

Jie Wu, Huangxian Ju, Qian Yu, Yuan Chen, Xu Cao
article en
8 citations

Abstract

This work proposes a highly sensitive, simple, and reliable electrochemiluminescence (ECL) DNA methylation biosensing platform by employing DNA-functionalized magnetic beads (DNA-MBs) for target capture and nanotag self-assembly aggregation for signal amplification. The target methylated DNA was first captured on DNA-MBs through base pairing recognition, and then its methylation sites were recognized by antibody-5mC (Ab-5mC). Afterward, a pair of antibodies functionalized [Ru(byp)<sub>3</sub>]<sup>2+</sup>-doped silica nanoparticles (Ab<sub>2</sub>-Ru@SiO<sub>2</sub> and Ab<sub>3</sub>-Ru@SiO<sub>2</sub>) was layer-by-layer assembled on Ab-5mC for amplified signal transduction. The sensing beads could be transferred to screen-printed carbon electrodes (SPCEs) for ECL curve detection via photomultiplier tube or to gold-coated indium tin oxide (Au/ITO) arrays for high-throughput imaging detection. As the nanotag assembly layers increased from 1 to 3, the detection sensitivities of SPCE-based curve detection and Au/ITO-based imaging detection were enhanced 7-fold and 3-fold, achieving detection limits down to 0.8 pM and 0.9 fM, respectively. The nanotags showed good stability, with storage times of 300 days for Ru@SiO<sub>2</sub> and 60 days for Ab-Ru@SiO<sub>2</sub>, respectively. This method is universal and could be applied to detect different methylated DNAs by using their corresponding DNA-MBs. The proposed ECL biosensing platform possessed advantages of high sensitivity, good diversity, and practicality, showing potential for high-throughput DNA methylation detection in clinical diagnosis.

Analytical ChemistryVol. 97(18)
Nanjing University (CN)
Canon Medical Systems Corporation, State Key Laboratory of Analytical Chemistry for Life Sciences
Openalex Percentile: Top 3%
Advanced biosensing and bioanalysis techniques
6.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.