Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2025-04-26
DOI
https://doi.org/10.3390/atmos16050502
Citations
5
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
4.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Prakash Gautam, John G. Watson, A. P. Ramirez, Judith C. Chow et al.
5 citations
Atmosphere
Air Quality Monitoring and Forecasting
4.00
article

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Prakash Gautam, John G. Watson, A. P. Ramirez, Judith C. Chow, Hans Moosmüller, W. P. Arnott, Xiaoliang Wang, Scott Bair
article en
5 citations

Abstract

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

AtmosphereVol. 16(5)
University of Nevada, Reno (US), Desert Research Institute (US)
U.S. Department of Energy
Openalex Percentile: Top 7%
Air Quality Monitoring and Forecasting
4.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions — Prakash Gautam, John G. Watson, et al. · Atmosphere (2025) | TGRS Research Map | TGRS