Automated micro-CT morphometry of femoral biopsies from hip arthroplasties: adaptive local thresholding, volume of interest wrapping and removal of debris

Bone biopsies are an important biological tool for investigating bone microarchitecture, which can be non-destructively imaged in 3D via micro-computed tomography (micro-CT). Image thresholding and delineation of a region of interest (ROI) are prerequisites for quantifying bone parameters. Validated automatic protocols enable quantification of biopsies that contain trabecular and cortical bone. However, irregularly shaped trabecular bone biopsies with peripheral and internal debris have required manual ROI delineation, which is time-intensive and subject to inter and intra-observer variance. We hypothesise that an automated workflow will be a suitable alternative to overcome these issues and objectively determine bone microarchitecture in surgical biopsies, at higher throughput suitable for clinical studies. Hence, the aim of this study was to develop an objective, reproducible and automated workflow to analyse microarchitecture of trabecular bone biopsies. To accomplish this aim, we tested six different methods of ROI delineation: a whole biopsy ROI, and both manual (slow) and automatically delineated (fast) reduced ROIs to remove peripheral debris, each with (adaptive thresholding and a set of morphological operations to remove debris) and without (global thresholding) processing in a subset (n = 8) of intertrochanteric femoral biopsies obtained from patients undergoing hip arthroplasty. Number of objects, bone volume to tissue volume (BV/TV), trabecular separation (Tb.Sp), structure model index (SMI) and Euler number and trabecular pattern factor (Tb.Pf) were compared between the six workflows using Friedman's test and post-hoc pairwise comparisons with Bonferroni correction was performed. The two most reproducible techniques were tested for validation in a larger cohort of arthroplasty patients (n = 60) and results were compared with appropriate t-test. Subset analysis indicated that the manual and automated ROI with processing increased the ability to resolve real differences between these groups in parameters BV/TV, Tb.Sp and Euler number compared to with no processing and whole biopsy ROI approach. A validation cohort consisted of thirty osteoarthritis patients with a mean age 68.25 ± 8.64 and thirty neck of femur fracture with a mean age 82.4 ± 8.9. The manual technique failed to detect differences in BV/TV, SMI and Tb.Pf between the two patient groups (p > 0.05, for all) while the automated workflow demonstrated significant differences in these parameters between the OA and the NOF patients (p < 0.05). This is probably due to irregularity in the reference VOI volume introduced by manual ROI delineation reducing morphometric precision, compared to the automated method. In conclusion, our automated workflow performed better than customary practice; it represents a user-independent, high throughput technique to measure bone microarchitecture accurately in surgical biopsies.

Authors

Institutions

Publication Details

Journal
Bone
Published
2025-04-29
DOI
https://doi.org/10.1016/j.bone.2025.117502
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated micro-CT morphometry of femoral biopsies from hip arthroplasties: adaptive local thresholding, volume of interest wrapping and removal of debris

Lucian B. Solomon, Stuart A. Callary, Phil Salmon, Agatha Labrinidis et al.
Bone
Orthopaedic implants and arthroplasty
article

Automated micro-CT morphometry of femoral biopsies from hip arthroplasties: adaptive local thresholding, volume of interest wrapping and removal of debris

Lucian B. Solomon, Stuart A. Callary, Phil Salmon, Agatha Labrinidis, Boopalan Ramasamy, Xiangyu Dong, Deepti Sharma, Chris Schultz
article en

Abstract

Bone biopsies are an important biological tool for investigating bone microarchitecture, which can be non-destructively imaged in 3D via micro-computed tomography (micro-CT). Image thresholding and delineation of a region of interest (ROI) are prerequisites for quantifying bone parameters. Validated automatic protocols enable quantification of biopsies that contain trabecular and cortical bone. However, irregularly shaped trabecular bone biopsies with peripheral and internal debris have required manual ROI delineation, which is time-intensive and subject to inter and intra-observer variance. We hypothesise that an automated workflow will be a suitable alternative to overcome these issues and objectively determine bone microarchitecture in surgical biopsies, at higher throughput suitable for clinical studies. Hence, the aim of this study was to develop an objective, reproducible and automated workflow to analyse microarchitecture of trabecular bone biopsies. To accomplish this aim, we tested six different methods of ROI delineation: a whole biopsy ROI, and both manual (slow) and automatically delineated (fast) reduced ROIs to remove peripheral debris, each with (adaptive thresholding and a set of morphological operations to remove debris) and without (global thresholding) processing in a subset (n = 8) of intertrochanteric femoral biopsies obtained from patients undergoing hip arthroplasty. Number of objects, bone volume to tissue volume (BV/TV), trabecular separation (Tb.Sp), structure model index (SMI) and Euler number and trabecular pattern factor (Tb.Pf) were compared between the six workflows using Friedman's test and post-hoc pairwise comparisons with Bonferroni correction was performed. The two most reproducible techniques were tested for validation in a larger cohort of arthroplasty patients (n = 60) and results were compared with appropriate t-test. Subset analysis indicated that the manual and automated ROI with processing increased the ability to resolve real differences between these groups in parameters BV/TV, Tb.Sp and Euler number compared to with no processing and whole biopsy ROI approach. A validation cohort consisted of thirty osteoarthritis patients with a mean age 68.25 ± 8.64 and thirty neck of femur fracture with a mean age 82.4 ± 8.9. The manual technique failed to detect differences in BV/TV, SMI and Tb.Pf between the two patient groups (p > 0.05, for all) while the automated workflow demonstrated significant differences in these parameters between the OA and the NOF patients (p < 0.05). This is probably due to irregularity in the reference VOI volume introduced by manual ROI delineation reducing morphometric precision, compared to the automated method. In conclusion, our automated workflow performed better than customary practice; it represents a user-independent, high throughput technique to measure bone microarchitecture accurately in surgical biopsies.

BoneVol. 197
Royal Adelaide Hospital (AU), Bruker (United States) (US), Anhui Medical University (CN), Second Affiliated Hospital of Anhui Medical University (CN), The University of Adelaide (AU)
Hospital Research Foundation, University of Adelaide, Faculty of Health and Medical Sciences, University of Western Australia, Barwon Health Foundation
Openalex Percentile: Top 84%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.