Research on the Mechanism of Electrical Erosion Accelerating Failure in High-Current Pulse Thyristor-Based Switches

High-current pulse thyristor-based switches operate under high-current pulse conditions and are subjected to coupled electromagnetic-thermomechanical stresses, resulting in the progressive development of thermal fatigue-induced failure mechanisms. The study revealed that localized overheating triggers electrical erosion of the aluminum layer, which further accelerates the thermal fatigue failure of high-current switches. To investigate this phenomenon, a microscopic model of the silicon-aluminum interface incorporating surface roughness effects was developed to quantify the transient temperature rise and electrical erosion threshold under varying pulsed current conditions, with experimental validation demonstrating strong agreement. Furthermore, using a thermal network model, we established a correlation between the electrical erosion threshold and the average junction temperature for different high-current pulses and clamping stresses, thereby defining the operational range for electrical erosion in high-current pulse thyristor-based switches. This provides theoretical guidance for the reliable operation of these switches.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Device and Materials Reliability
Published
2025-04-29
DOI
https://doi.org/10.1109/tdmr.2025.3565618
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Mechanism of Electrical Erosion Accelerating Failure in High-Current Pulse Thyristor-Based Switches

Liuxia Li, Fuchang Lin, Yi Liu, Yunxin Miao et al.
IEEE Transactions on Device and Materials Reliability
Vacuum and Plasma Arcs
article

Research on the Mechanism of Electrical Erosion Accelerating Failure in High-Current Pulse Thyristor-Based Switches

Liuxia Li, Fuchang Lin, Yi Liu, Yunxin Miao, Shiyun Xiao
article en

Abstract

High-current pulse thyristor-based switches operate under high-current pulse conditions and are subjected to coupled electromagnetic-thermomechanical stresses, resulting in the progressive development of thermal fatigue-induced failure mechanisms. The study revealed that localized overheating triggers electrical erosion of the aluminum layer, which further accelerates the thermal fatigue failure of high-current switches. To investigate this phenomenon, a microscopic model of the silicon-aluminum interface incorporating surface roughness effects was developed to quantify the transient temperature rise and electrical erosion threshold under varying pulsed current conditions, with experimental validation demonstrating strong agreement. Furthermore, using a thermal network model, we established a correlation between the electrical erosion threshold and the average junction temperature for different high-current pulses and clamping stresses, thereby defining the operational range for electrical erosion in high-current pulse thyristor-based switches. This provides theoretical guidance for the reliable operation of these switches.

IEEE Transactions on Device and Materials ReliabilityVol. 25(2)
Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 93%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.