Traceability Method of Measuring System for Arbitrary High-Voltage and High-Current Impulses

High-voltage and high-current impulse waveforms, characterized by a diverse frequency spectrum, pose challenges for accurate traceability to national standards. Traditional methods for tracing impulse quantities to a single-frequency measurement standard are not universally applicable. This paper introduces a novel approach that establishes a general traceability method by mapping the impulse scale factor to a multi-frequency AC scale factor based on the energy spectrum, enabling indirect traceability to the power frequency standard under high-voltage or high-current conditions. A full-waveform inversion method is employed that integrates the frequency spectrum of measured impulse waveforms using fast Fourier transform (FFT) with the frequency response characteristics of the measuring system, which are determined through convolution based on square wave responses. This approach facilitates traceability of time parameters for arbitrary impulse waveforms. Experimental results demonstrate that the resistive impulse voltage divider's scale factor uncertainties at low and high voltages are 3.100×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-4</sup> and 1.344×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup>, respectively. Additionally, the uncertainties for the T<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> and T<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> parameters of the inverted waveform of the attenuator are within 0.45% and 0.03%, respectively. These findings validate the effectiveness of our traceability theory.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-29
DOI
https://doi.org/10.1109/jsen.2025.3560930
Citations
1
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
1.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Traceability Method of Measuring System for Arbitrary High-Voltage and High-Current Impulses

Zhaozhi Long, Yinglong Diao, Liuxia Li, Fuchang Lin et al.
1 citations
IEEE Sensors Journal
Sensor Technology and Measurement Systems
1.49
article

Traceability Method of Measuring System for Arbitrary High-Voltage and High-Current Impulses

Zhaozhi Long, Yinglong Diao, Liuxia Li, Fuchang Lin, Yi Liu, Wenting Li, Jiawei Fan, Ning Yang
article en
1 citations

Abstract

High-voltage and high-current impulse waveforms, characterized by a diverse frequency spectrum, pose challenges for accurate traceability to national standards. Traditional methods for tracing impulse quantities to a single-frequency measurement standard are not universally applicable. This paper introduces a novel approach that establishes a general traceability method by mapping the impulse scale factor to a multi-frequency AC scale factor based on the energy spectrum, enabling indirect traceability to the power frequency standard under high-voltage or high-current conditions. A full-waveform inversion method is employed that integrates the frequency spectrum of measured impulse waveforms using fast Fourier transform (FFT) with the frequency response characteristics of the measuring system, which are determined through convolution based on square wave responses. This approach facilitates traceability of time parameters for arbitrary impulse waveforms. Experimental results demonstrate that the resistive impulse voltage divider's scale factor uncertainties at low and high voltages are 3.100×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-4</sup> and 1.344×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup>, respectively. Additionally, the uncertainties for the T<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> and T<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> parameters of the inverted waveform of the attenuator are within 0.45% and 0.03%, respectively. These findings validate the effectiveness of our traceability theory.

IEEE Sensors JournalVol. 25(12)
North China Electric Power University (CN), China Electric Power Research Institute, Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 18%
Sensor Technology and Measurement Systems
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.