Geant4 Monte Carlo study of the relation between image blurring and depth of optical photons produced using kilo-voltage x-rays and micro-columnar scintillators

X-ray detectors, which generally enjoy very good detection efficiency and spatial resolution, have many applications including in radiography and basic research. Many of the existing radiographic methods are extremely inefficient and time-consuming, making them improper for real-time applications. A solution to avoid such a problem has been to develop structured scintillation films such as CsI, which have high density and fast response, and at the same time, have the possibility of being grown as compact micrometer structures – suggesting a way to attain better image qualities. Employing the Geant4 Monte Carlo toolkit, we have used a simple geometry to serve as a radiography system, which includes a polymer layer as a camera, a structured layer of micro-columnar scintillators as x-ray converters, and an aluminum layer as a light reflector. Hence, for pencil-beam x-rays we investigated the dependence of blurring on the production depth of the resulting optical photons.

Institutions

Publication Details

Journal
Iranian Journal of Physics Research
Published
2025-03-01
DOI
https://doi.org/10.47176/ijpr.24.4.41878
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geant4 Monte Carlo study of the relation between image blurring and depth of optical photons produced using kilo-voltage x-rays and micro-columnar scintillators

Iranian Journal of Physics Research
Advanced X-ray and CT Imaging
article

Geant4 Monte Carlo study of the relation between image blurring and depth of optical photons produced using kilo-voltage x-rays and micro-columnar scintillators

article en

Abstract

X-ray detectors, which generally enjoy very good detection efficiency and spatial resolution, have many applications including in radiography and basic research. Many of the existing radiographic methods are extremely inefficient and time-consuming, making them improper for real-time applications. A solution to avoid such a problem has been to develop structured scintillation films such as CsI, which have high density and fast response, and at the same time, have the possibility of being grown as compact micrometer structures – suggesting a way to attain better image qualities. Employing the Geant4 Monte Carlo toolkit, we have used a simple geometry to serve as a radiography system, which includes a polymer layer as a camera, a structured layer of micro-columnar scintillators as x-ray converters, and an aluminum layer as a light reflector. Hence, for pencil-beam x-rays we investigated the dependence of blurring on the production depth of the resulting optical photons.

Iranian Journal of Physics ResearchVol. 24(4)
Shiraz University (IR)
Openalex Percentile: Top 92%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Geant4 Monte Carlo study of the relation between image blurring and depth of optical photons produced using kilo-voltage x-rays and micro-columnar scintillators · Iranian Journal of Physics Research (2025) | TGRS Research Map | TGRS