Monte Carlo simulations of 5/8′′ NaI gamma camera detector response in radiological emergency preparedness

Following a radiological or nuclear (RN) event there is a need for measurement equipment readily available for estimation of internal contamination. Previous studies have shown that the gamma camera is a feasible tool for estimation of whole-body activity for relevant radionuclides during the recovery phase of an accident, e.g. by using whole-spectrum analysis. However, this technique is limited by the difficulties to interpret the spectral information in cases where more than one radionuclide is present in the subject. In this study, a Monte Carlo (MC) model of a gamma camera with a crystal thickness of 5/8'' was constructed using the Geant4 based MC software GATE to better understand the spectral information from multiple contaminants and to facilitate calibration for various radionuclides and contamination scenarios with several radionuclides present. The validation of the model showed good agreement with measurement data, within 15% deviation, which is an uncertainty generally accepted for RN event scenarios. The model was used to simulate the gamma camera detector response for relevant contamination scenarios in the short and the long term perspective following a nuclear power plant accident.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2025-04-29
DOI
https://doi.org/10.1088/1361-6498/add1e6
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte Carlo simulations of 5/8′′ NaI gamma camera detector response in radiological emergency preparedness

Martin Hjellström, Mats Isaksson
Journal of Radiological Protection
Radiation Detection and Scintillator Technologies
article

Monte Carlo simulations of 5/8′′ NaI gamma camera detector response in radiological emergency preparedness

Martin Hjellström, Mats Isaksson
article en

Abstract

Following a radiological or nuclear (RN) event there is a need for measurement equipment readily available for estimation of internal contamination. Previous studies have shown that the gamma camera is a feasible tool for estimation of whole-body activity for relevant radionuclides during the recovery phase of an accident, e.g. by using whole-spectrum analysis. However, this technique is limited by the difficulties to interpret the spectral information in cases where more than one radionuclide is present in the subject. In this study, a Monte Carlo (MC) model of a gamma camera with a crystal thickness of 5/8'' was constructed using the Geant4 based MC software GATE to better understand the spectral information from multiple contaminants and to facilitate calibration for various radionuclides and contamination scenarios with several radionuclides present. The validation of the model showed good agreement with measurement data, within 15% deviation, which is an uncertainty generally accepted for RN event scenarios. The model was used to simulate the gamma camera detector response for relevant contamination scenarios in the short and the long term perspective following a nuclear power plant accident.

Journal of Radiological ProtectionVol. 45(2)
Sahlgrenska University Hospital (SE), University of Gothenburg (SE)
Myndigheten för Samhällsskydd och Beredskap, Strålsäkerhetsmyndigheten
Openalex Percentile: Top 89%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Monte Carlo simulations of 5/8′′ NaI gamma camera detector response in radiological emergency preparedness — Martin Hjellström, Mats Isaksson · Journal of Radiological Protection (2025) | TGRS Research Map | TGRS