A sensitive soma-localized red fluorescent calcium indicator for in vivo imaging of neuronal populations at single-cell resolution

Recent advancements in genetically encoded calcium indicators, particularly those based on green fluorescent proteins, have optimized their performance for monitoring neuronal activities in a variety of model organisms. However, progress in developing red-shifted GECIs, despite their advantages over green indicators, has been slower, resulting in fewer options for end users. In this study, we explored topological inversion and soma-targeting strategies, which are complementary to conventional mutagenesis, to re-engineer a red genetically encoded calcium indicator, FRCaMP, for enhanced in vivo performance. The resulting sensors, FRCaMPi and soma-targeted FRCaMPi (SomaFRCaMPi), exhibit up to 2-fold higher dynamic range and peak ΔF/F0 per single AP compared to widely used jRGECO1a in neurons both in culture and in vivo. Compared to jRGECO1a and FRCaMPi, SomaFRCaMPi reduces erroneous correlation of neuronal activity in the brains of mice and zebrafish by two- to 4-fold due to diminished neuropil contamination without compromising the signal-to-noise ratio. Under wide-field imaging in primary somatosensory and visual cortices in mice with high labeling density (80-90%), SomaFRCaMPi exhibits up to 40% higher SNR and decreased artifactual correlation across neurons. Altogether, SomaFRCaMPi improves the accuracy and scale of neuronal activity imaging at single-neuron resolution in densely labeled brain tissues due to a 2-3-fold enhanced automated neuronal segmentation, 50% higher fraction of responsive cells, up to 2-fold higher SNR compared to jRGECO1a. Our findings highlight the potential of SomaFRCaMPi, comparable to the most sensitive soma-targeted GCaMP, for precise spatial recording of neuronal populations using popular imaging modalities in model organisms such as zebrafish and mice.

Authors

Institutions

Publication Details

Journal
PLoS Biology
Published
2025-04-29
DOI
https://doi.org/10.1371/journal.pbio.3003048
Citations
3
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
4.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A sensitive soma-localized red fluorescent calcium indicator for in vivo imaging of neuronal populations at single-cell resolution

Tao Yang, Zengcai V. Guo, Xiaoting Sun, Shilin Fang et al.
3 citations
PLoS Biology
Advanced Fluorescence Microscopy Techniques
4.90
article

A sensitive soma-localized red fluorescent calcium indicator for in vivo imaging of neuronal populations at single-cell resolution

Tao Yang, Zengcai V. Guo, Xiaoting Sun, Shilin Fang, Jiewen Hu, Kiryl D. Piatkevich, Jonnathan Singh Alvarado, Zhiyuan Wang, Shihao Zhou, Fedor V. Subach, Young‐Gyu Yoon, Yu Mu, Qiyu Zhu, Minho Eom, Ran Chen, Yangdong Wang, Hanbin Zhang, Yuanping Dong, Oksana M. Subach, Praneel S. Sunkavalli
article en
3 citations

Abstract

Recent advancements in genetically encoded calcium indicators, particularly those based on green fluorescent proteins, have optimized their performance for monitoring neuronal activities in a variety of model organisms. However, progress in developing red-shifted GECIs, despite their advantages over green indicators, has been slower, resulting in fewer options for end users. In this study, we explored topological inversion and soma-targeting strategies, which are complementary to conventional mutagenesis, to re-engineer a red genetically encoded calcium indicator, FRCaMP, for enhanced in vivo performance. The resulting sensors, FRCaMPi and soma-targeted FRCaMPi (SomaFRCaMPi), exhibit up to 2-fold higher dynamic range and peak ΔF/F0 per single AP compared to widely used jRGECO1a in neurons both in culture and in vivo. Compared to jRGECO1a and FRCaMPi, SomaFRCaMPi reduces erroneous correlation of neuronal activity in the brains of mice and zebrafish by two- to 4-fold due to diminished neuropil contamination without compromising the signal-to-noise ratio. Under wide-field imaging in primary somatosensory and visual cortices in mice with high labeling density (80-90%), SomaFRCaMPi exhibits up to 40% higher SNR and decreased artifactual correlation across neurons. Altogether, SomaFRCaMPi improves the accuracy and scale of neuronal activity imaging at single-neuron resolution in densely labeled brain tissues due to a 2-3-fold enhanced automated neuronal segmentation, 50% higher fraction of responsive cells, up to 2-fold higher SNR compared to jRGECO1a. Our findings highlight the potential of SomaFRCaMPi, comparable to the most sensitive soma-targeted GCaMP, for precise spatial recording of neuronal populations using popular imaging modalities in model organisms such as zebrafish and mice.

PLoS BiologyVol. 23(4)
ON Semiconductor (United States) (US), Scripps Research Institute (US), Beth Israel Deaconess Medical Center (US), Korea Advanced Institute of Science and Technology (KR), Neurosciences Institute (US), Chinese Academy of Sciences (CN), Kurchatov Institute (RU), Westlake University (CN), Center for Excellence in Brain Science and Intelligence Technology (CN), Chinese Institute for Brain Research (CN), Center for Life Sciences (CN), University of Chinese Academy of Sciences (CN), Institute of Basic Medical Sciences of the Chinese Academy of Medical Sciences, Tsinghua University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 6%
Advanced Fluorescence Microscopy Techniques
4.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.