Long-term performance test of Cu canisters used for disposing of spent nuclear fuels under aerobic groundwater

Evaluating the long-term corrosion behavior of Cu under local groundwater is important for its use in fabricating disposal canisters. The long-term performance of KJ-I bentonite-embedded Cu disks was assessed for a testing period of 10 years. The results were compared with those obtained on MX-80 bentonite-embedded Cu disks. The disks retrieved from the MX-80 and KJ-I bentonites exhibited corrosion depths of 0.53 and 3.9 μm, respectively. The corrosion rate below 0.39 μm/year indicated that Ca-type KJ-I bentonite can also be used as a buffer material. The surface characterizations revealed the formation of a thin Cu oxide layer (∼0.5 μm) on the MX-80 bentonite-retrieved disk. A Cu 2 O layer (∼2 μm) was formed on the KJ-I bentonite-retrieved disk. During open-circuit potential measurements, the bentonite-embedded disk exhibited a potential below −125 mV, which is considerably lower than the pitting potential of Cu (∼250 mV), indicating that the occurrence of localized corrosion of Cu is largely reduced upon embedding in bentonite. This study demonstrates that KJ-I bentonite-embedded Cu canisters can be utilized for nuclear waste disposal under aerobic conditions.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-04-29
DOI
https://doi.org/10.1016/j.net.2025.103678
Citations
2
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-term performance test of Cu canisters used for disposing of spent nuclear fuels under aerobic groundwater

Junhyuk Jang, Minsoo Lee, Seok Yoon, Gha-Young Kim
2 citations
Nuclear Engineering and Technology
Nuclear Materials and Properties
1.04
article

Long-term performance test of Cu canisters used for disposing of spent nuclear fuels under aerobic groundwater

Junhyuk Jang, Minsoo Lee, Seok Yoon, Gha-Young Kim
article en
2 citations

Abstract

Evaluating the long-term corrosion behavior of Cu under local groundwater is important for its use in fabricating disposal canisters. The long-term performance of KJ-I bentonite-embedded Cu disks was assessed for a testing period of 10 years. The results were compared with those obtained on MX-80 bentonite-embedded Cu disks. The disks retrieved from the MX-80 and KJ-I bentonites exhibited corrosion depths of 0.53 and 3.9 μm, respectively. The corrosion rate below 0.39 μm/year indicated that Ca-type KJ-I bentonite can also be used as a buffer material. The surface characterizations revealed the formation of a thin Cu oxide layer (∼0.5 μm) on the MX-80 bentonite-retrieved disk. A Cu 2 O layer (∼2 μm) was formed on the KJ-I bentonite-retrieved disk. During open-circuit potential measurements, the bentonite-embedded disk exhibited a potential below −125 mV, which is considerably lower than the pitting potential of Cu (∼250 mV), indicating that the occurrence of localized corrosion of Cu is largely reduced upon embedding in bentonite. This study demonstrates that KJ-I bentonite-embedded Cu canisters can be utilized for nuclear waste disposal under aerobic conditions.

Nuclear Engineering and TechnologyVol. 57(9)
Korea Atomic Energy Research Institute (KR)
Openalex Percentile: Top 26%
Nuclear Materials and Properties
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.