Detection of Carbon Monoxide in Automobile Exhaust Based on Photoacoustic Spectroscopy

To enable the detection of carbon monoxide (CO) in automobile exhaust, this study designs and implements a CO detection system based on photoacoustic spectroscopy. By optimizing the excitation light source, photoacoustic cell, signal processing unit, and data acquisition module, the key challenges of sensitivity, stability, and signal-to-noise ratio in real-time monitoring are effectively addressed. Experimental results demonstrate that the system performs excellently within the concentration range of 120 ppm to 1200 ppm, with a maximum relative error not exceeding 1.8%. These results verify the system's high sensitivity and accuracy. The system shows significant potential for widespread application, providing reliable data support for automobile exhaust monitoring.

Authors

Institutions

Publication Details

Journal
Journal of engineering system.
Published
2024-12-01
DOI
https://doi.org/10.62517/jes.202402402
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Carbon Monoxide in Automobile Exhaust Based on Photoacoustic Spectroscopy

Yuanhan Chen
1 citations
Journal of engineering system.
Spectroscopy and Laser Applications
article

Detection of Carbon Monoxide in Automobile Exhaust Based on Photoacoustic Spectroscopy

Yuanhan Chen
article en
1 citations

Abstract

To enable the detection of carbon monoxide (CO) in automobile exhaust, this study designs and implements a CO detection system based on photoacoustic spectroscopy. By optimizing the excitation light source, photoacoustic cell, signal processing unit, and data acquisition module, the key challenges of sensitivity, stability, and signal-to-noise ratio in real-time monitoring are effectively addressed. Experimental results demonstrate that the system performs excellently within the concentration range of 120 ppm to 1200 ppm, with a maximum relative error not exceeding 1.8%. These results verify the system's high sensitivity and accuracy. The system shows significant potential for widespread application, providing reliable data support for automobile exhaust monitoring.

Journal of engineering system.Vol. 2(4)
Dalian University (CN)
Openalex Percentile: Top 79%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.