Mechanical Container Closure Integrity Test: A Method for Cartridge Systems

A cartridge container closure integrity control strategy may leverage a combination of test methods to ensure that drug products in the assembled container system are protected from an exchange with the external environment. These methods provide evidence supporting the suitability of the container closure system; however, some methods involve extended test times, complex setups, subjective interpretation, and are destructive. A method that mitigates such factors was developed to improve upon testing utilized within the control strategy. Reviewing the underlying principles of internal methods and external standards resulted in two potential paths, a force decay method and a constant force method, to improve on the cartridge control strategy using a linear mechanical testing system. The force decay method monitors the force decay signal obtained from applying a predetermined force and holding the displacement constant for a desired time frame. The constant force method monitors the displacement signal obtained from applying a predetermined force and holding the force constant for a desired time frame. Supplementing the experimental data generated by both methods with a finite element analysis along with a first principles derivation of the system response aided in a recommendation to utilize the constant force method for cartridge container closure integrity leak testing. The constant force method was then optimized to attain the best signal response for leak detection and ensure a robust method. The data generated in this article support the viability of using the constant force mechanical container closure integrity test method for improving the in-process container closure integrity testing strategy for solution products.

Authors

Institutions

Publication Details

Journal
PDA Journal of Pharmaceutical Science and Technology
Published
2025-04-29
DOI
https://doi.org/10.5731/pdajpst.2024.012941
Primary Topic
Electronic Packaging and Soldering Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Container Closure Integrity Test: A Method for Cartridge Systems

Henri Hebting, Meng Zhao, Lei Li, Louis W. Schultz et al.
PDA Journal of Pharmaceutical Science and Technology
Electronic Packaging and Soldering Technologies
article

Mechanical Container Closure Integrity Test: A Method for Cartridge Systems

Henri Hebting, Meng Zhao, Lei Li, Louis W. Schultz, Michael W Foubert, Benoit Lux, Julie Bourguard, Jason D Marlin, Matthew S Huser
article en

Abstract

A cartridge container closure integrity control strategy may leverage a combination of test methods to ensure that drug products in the assembled container system are protected from an exchange with the external environment. These methods provide evidence supporting the suitability of the container closure system; however, some methods involve extended test times, complex setups, subjective interpretation, and are destructive. A method that mitigates such factors was developed to improve upon testing utilized within the control strategy. Reviewing the underlying principles of internal methods and external standards resulted in two potential paths, a force decay method and a constant force method, to improve on the cartridge control strategy using a linear mechanical testing system. The force decay method monitors the force decay signal obtained from applying a predetermined force and holding the displacement constant for a desired time frame. The constant force method monitors the displacement signal obtained from applying a predetermined force and holding the force constant for a desired time frame. Supplementing the experimental data generated by both methods with a finite element analysis along with a first principles derivation of the system response aided in a recommendation to utilize the constant force method for cartridge container closure integrity leak testing. The constant force method was then optimized to attain the best signal response for leak detection and ensure a robust method. The data generated in this article support the viability of using the constant force mechanical container closure integrity test method for improving the in-process container closure integrity testing strategy for solution products.

PDA Journal of Pharmaceutical Science and TechnologyVol. 79(3)
Eli Lilly (United States) (US)
Openalex Percentile: Top 93%
Electronic Packaging and Soldering Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.