Preliminary Assessment of Air Pollution in the Archaeological Museum of Naples (Italy): Long Term Monitoring of Nitrogen Dioxide and Nitrous Acid

A project to assess air pollution at the National Archeological Museum in Naples was carried out. The main goal of the project was to develop and test a reliable yet simple monitoring system to be adopted at the same time in several exposition rooms. Nitrogen dioxide, hydrogen chloride, nitrous acid, and sulphur dioxide were the chemical species addressed by the technique. Monitoring was simultaneously performed in five rooms, and pollutant concentrations were determined using two passive samplers. The sampling time was approximately one month per period. In addition to passive samplers, environmental data loggers were used to obtain temperature and relative humidity data. Results show high concentrations of nitrogen dioxide inside rooms, which were consistent with those found in outdoor environments and are close to the values calculated considering the air exchange rates, estimated through time gradients of ambient temperature. The minimum values were recorded in a basement room that had a low ventilation rate. The conversion of nitrogen dioxide to real surfaces produces nitric acid and nitrous acid. Large amounts of nitrous acid, up to 15 µg/m3, were found in exposition rooms, with maximum values in the basement room, where the air exchange rate is limited, and the surface-to-volume ratio is the highest among the monitored rooms. Data analysis demonstrated that the system could discriminate between nitrous acid and nitrogen dioxide. The results show that, for the first time, passive samplers can overcome the problem of mutual interference between nitrogen-containing species. Nitrates and nitrites found in the alkaline passive sampler were generally found not to be interfered by nitrogen dioxide. Nitric acid was also found in the gas phase, likely generated by dissociation of ammonium nitrate in particulate matter. Hydrogen chloride and sulphur dioxide were present at few µg/m3. Nitrous acid is the most relevant acidic species found indoors. The presence of pollutants was discussed in terms of the reliability of the analytical procedure and its significance for indoor air pollution.

Authors

Institutions

Publication Details

Journal
Air
Published
2025-04-29
DOI
https://doi.org/10.3390/air3020012
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary Assessment of Air Pollution in the Archaeological Museum of Naples (Italy): Long Term Monitoring of Nitrogen Dioxide and Nitrous Acid

Cristiana Barandoni, I. Allegrini, Federica Valentini, Camilla Zaratti et al.
Air
Conservation Techniques and Studies
article

Preliminary Assessment of Air Pollution in the Archaeological Museum of Naples (Italy): Long Term Monitoring of Nitrogen Dioxide and Nitrous Acid

Cristiana Barandoni, I. Allegrini, Federica Valentini, Camilla Zaratti, Irene Angela Colasanti, Andrea Macchia, Anna Neri
article en

Abstract

A project to assess air pollution at the National Archeological Museum in Naples was carried out. The main goal of the project was to develop and test a reliable yet simple monitoring system to be adopted at the same time in several exposition rooms. Nitrogen dioxide, hydrogen chloride, nitrous acid, and sulphur dioxide were the chemical species addressed by the technique. Monitoring was simultaneously performed in five rooms, and pollutant concentrations were determined using two passive samplers. The sampling time was approximately one month per period. In addition to passive samplers, environmental data loggers were used to obtain temperature and relative humidity data. Results show high concentrations of nitrogen dioxide inside rooms, which were consistent with those found in outdoor environments and are close to the values calculated considering the air exchange rates, estimated through time gradients of ambient temperature. The minimum values were recorded in a basement room that had a low ventilation rate. The conversion of nitrogen dioxide to real surfaces produces nitric acid and nitrous acid. Large amounts of nitrous acid, up to 15 µg/m3, were found in exposition rooms, with maximum values in the basement room, where the air exchange rate is limited, and the surface-to-volume ratio is the highest among the monitored rooms. Data analysis demonstrated that the system could discriminate between nitrous acid and nitrogen dioxide. The results show that, for the first time, passive samplers can overcome the problem of mutual interference between nitrogen-containing species. Nitrates and nitrites found in the alkaline passive sampler were generally found not to be interfered by nitrogen dioxide. Nitric acid was also found in the gas phase, likely generated by dissociation of ammonium nitrate in particulate matter. Hydrogen chloride and sulphur dioxide were present at few µg/m3. Nitrous acid is the most relevant acidic species found indoors. The presence of pollutants was discussed in terms of the reliability of the analytical procedure and its significance for indoor air pollution.

AirVol. 3(2)
University of Rome Tor Vergata (IT), National Archaeological Museum (IT), University of Calabria (IT)
Openalex Percentile: Top 90%
Conservation Techniques and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.