[Stroke-p2pHD: Cross-modality generation model of cerebral infarction from CT to DWI images].

Among numerous medical imaging modalities, diffusion weighted imaging (DWI) is extremely sensitive to acute ischemic stroke lesions, especially small infarcts. However, magnetic resonance imaging is time-consuming and expensive, and it is also prone to interference from metal implants. Therefore, the aim of this study is to design a medical image synthesis method based on generative adversarial network, Stroke-p2pHD, for synthesizing DWI images from computed tomography (CT). Stroke-p2pHD consisted of a generator that effectively fused local image features and global context information (Global_to_Local) and a multi-scale discriminator (M <sup>2</sup>Dis). Specifically, in the Global_to_Local generator, a fully convolutional Transformer (FCT) and a local attention module (LAM) were integrated to achieve the synthesis of detailed information such as textures and lesions in DWI images. In the M <sup>2</sup>Dis discriminator, a multi-scale convolutional network was adopted to perform the discrimination function of the input images. Meanwhile, an optimization balance with the Global_to_Local generator was ensured and the consistency of features in each layer of the M <sup>2</sup>Dis discriminator was constrained. In this study, the public Acute Ischemic Stroke Dataset (AISD) and the acute cerebral infarction dataset from Yantaishan Hospital were used to verify the performance of the Stroke-p2pHD model in synthesizing DWI based on CT. Compared with other methods, the Stroke-p2pHD model showed excellent quantitative results (mean-square error = 0.008, peak signal-to-noise ratio = 23.766, structural similarity = 0.743). At the same time, relevant experimental analyses such as computational efficiency verify that the Stroke-p2pHD model has great potential for clinical applications.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-04-25
DOI
https://doi.org/10.7507/1001-5515.202407017
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Stroke-p2pHD: Cross-modality generation model of cerebral infarction from CT to DWI images].

Zhimeng Zou, Qiang Zheng, Nan Hao, Qing Wang et al.
PubMed
Radiomics and Machine Learning in Medical Imaging
article

[Stroke-p2pHD: Cross-modality generation model of cerebral infarction from CT to DWI images].

Zhimeng Zou, Qiang Zheng, Nan Hao, Qing Wang, Xinyue Liu, Xinyao Zhao
article en

Abstract

Among numerous medical imaging modalities, diffusion weighted imaging (DWI) is extremely sensitive to acute ischemic stroke lesions, especially small infarcts. However, magnetic resonance imaging is time-consuming and expensive, and it is also prone to interference from metal implants. Therefore, the aim of this study is to design a medical image synthesis method based on generative adversarial network, Stroke-p2pHD, for synthesizing DWI images from computed tomography (CT). Stroke-p2pHD consisted of a generator that effectively fused local image features and global context information (Global_to_Local) and a multi-scale discriminator (M <sup>2</sup>Dis). Specifically, in the Global_to_Local generator, a fully convolutional Transformer (FCT) and a local attention module (LAM) were integrated to achieve the synthesis of detailed information such as textures and lesions in DWI images. In the M <sup>2</sup>Dis discriminator, a multi-scale convolutional network was adopted to perform the discrimination function of the input images. Meanwhile, an optimization balance with the Global_to_Local generator was ensured and the consistency of features in each layer of the M <sup>2</sup>Dis discriminator was constrained. In this study, the public Acute Ischemic Stroke Dataset (AISD) and the acute cerebral infarction dataset from Yantaishan Hospital were used to verify the performance of the Stroke-p2pHD model in synthesizing DWI based on CT. Compared with other methods, the Stroke-p2pHD model showed excellent quantitative results (mean-square error = 0.008, peak signal-to-noise ratio = 23.766, structural similarity = 0.743). At the same time, relevant experimental analyses such as computational efficiency verify that the Stroke-p2pHD model has great potential for clinical applications.

PubMedVol. 42(2)
Yantai University (CN), Jining Traditional Chinese Medicine Hospital (CN), Yantaishan Hospital (CN)
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.