[Research on a portable electrical impedance tomography system for evaluating blood compatibility of biomaterials].

The evaluation of blood compatibility of biomaterials is crucial for ensuring the clinical safety of implantable medical devices. To address the limitations of traditional testing methods in real-time monitoring and electrical property analysis, this study developed a portable electrical impedance tomography (EIT) system. The system uses a 16-electrode design, operates within a frequency range of 1 to 500 kHz, achieves a signal to noise ratio (SNR) of 69.54 dB at 50 kHz, and has a data collection speed of 20 frames per second. Experimental results show that the EIT system developed in this study is highly consistent with a microplate reader ( <i>R</i> <sup>2</sup>=0.97) in detecting the hemolytic behavior of industrial-grade titanium (TA3) and titanium alloy-titanium 6 aluminum 4 vanadium (TC4) in anticoagulated bovine blood. Additionally, with the support of a multimodal image fusion Gauss-Newton one-step iterative algorithm, the system can accurately locate and monitor in real-time the dynamic changes in blood permeation and coagulation caused by TC4 <i>in vivo</i>. In conclusion, the EIT system developed in this study provides a new and effective method for evaluating the blood compatibility of biomaterials.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-04-25
DOI
https://doi.org/10.7507/1001-5515.202410058
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Research on a portable electrical impedance tomography system for evaluating blood compatibility of biomaterials].

Bo Che, Huaihao Chen, P. Peng, Linhong Deng et al.
PubMed
Electrical and Bioimpedance Tomography
article

[Research on a portable electrical impedance tomography system for evaluating blood compatibility of biomaterials].

Bo Che, Huaihao Chen, P. Peng, Linhong Deng, Xuan Li, C. Fan, Lei Liu, Teng Luo
article en

Abstract

The evaluation of blood compatibility of biomaterials is crucial for ensuring the clinical safety of implantable medical devices. To address the limitations of traditional testing methods in real-time monitoring and electrical property analysis, this study developed a portable electrical impedance tomography (EIT) system. The system uses a 16-electrode design, operates within a frequency range of 1 to 500 kHz, achieves a signal to noise ratio (SNR) of 69.54 dB at 50 kHz, and has a data collection speed of 20 frames per second. Experimental results show that the EIT system developed in this study is highly consistent with a microplate reader ( <i>R</i> <sup>2</sup>=0.97) in detecting the hemolytic behavior of industrial-grade titanium (TA3) and titanium alloy-titanium 6 aluminum 4 vanadium (TC4) in anticoagulated bovine blood. Additionally, with the support of a multimodal image fusion Gauss-Newton one-step iterative algorithm, the system can accurately locate and monitor in real-time the dynamic changes in blood permeation and coagulation caused by TC4 <i>in vivo</i>. In conclusion, the EIT system developed in this study provides a new and effective method for evaluating the blood compatibility of biomaterials.

PubMedVol. 42(2)
Changzhou University (CN)
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[Research on a portable electrical impedance tomography system for evaluating blood compatibility of biomaterials]. — Bo Che, Huaihao Chen, et al. · PubMed (2025) | TGRS Research Map | TGRS