Test-Retest Reliability of Isokinetic Strength Measurement in Standardized and Lengthened Hamstring Positions Among Healthy Adults

Introduction: Strength is a key modifiable risk factor for hamstring strains with significant differences between injured and non-injured sides in the lengthened position. Ensuring the test-retest reliability of measurement protocols ensures consistent injury prevention, rehabilitation and return-to-sport planning. Objective: To evaluate the test-retest reliability of hamstring strength protocols in both standardized and lengthened positions among healthy adults. Study Design: Test-retest reliability study Setting: Human Performance Laboratory, Fr. Roque Ruano building, University of Santo Tomas, Espana Manila Participants: Ten healthy adults (six males and four females; mean age: 26.5 ± 4.03 years) Main Outcome Measures: Absolute and relative peak torque for concentric and eccentric hamstring and quadriceps were measured at 60°/sec, 180°/sec and 240°/sec in the standardized position (hip and knee flexed at 90°). In the lengthened position (hip flexed at 85° and knee at 30°), isometric knee flexion and peak torque for concentric and eccentric hamstring and quadriceps were assessed at 60°/sec and 180°/sec. Strength ratios were calculated for both positions. Results: Intraclass Correlation Coefficient (ICC) values demonstrated good to excellent reliability for peak torque measurements, with higher reliability in the standardized position (ICC 0.83-0.94) than in the lengthened position (ICC 0.79-0.96). Conventional and functional ratios varied, with lower ICCs for the right leg in the standardized position (ICC 0.32-0.92) and moderate to good reliability in the lengthened position (ICC 0.63-0.87). Conclusion: Standardized and lengthened positions provide reliable assessments of absolute and relative peak torque for hamstring and quadriceps muscles during concentric and eccentric contractions across all speeds, including conventional and functional strength ratios.

Authors

Publication Details

Journal
Journal of Medicine University of Santo Tomas
Published
2025-04-27
DOI
https://doi.org/10.35460/2546-1621.2024-0176
Primary Topic
Sports injuries and prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test-Retest Reliability of Isokinetic Strength Measurement in Standardized and Lengthened Hamstring Positions Among Healthy Adults

Helen Banwell, Maria Belinda Cristina C. Fidel, Consuelo G. Suarez
Journal of Medicine University of Santo Tomas
Sports injuries and prevention
article

Test-Retest Reliability of Isokinetic Strength Measurement in Standardized and Lengthened Hamstring Positions Among Healthy Adults

Helen Banwell, Maria Belinda Cristina C. Fidel, Consuelo G. Suarez
article en

Abstract

Introduction: Strength is a key modifiable risk factor for hamstring strains with significant differences between injured and non-injured sides in the lengthened position. Ensuring the test-retest reliability of measurement protocols ensures consistent injury prevention, rehabilitation and return-to-sport planning. Objective: To evaluate the test-retest reliability of hamstring strength protocols in both standardized and lengthened positions among healthy adults. Study Design: Test-retest reliability study Setting: Human Performance Laboratory, Fr. Roque Ruano building, University of Santo Tomas, Espana Manila Participants: Ten healthy adults (six males and four females; mean age: 26.5 ± 4.03 years) Main Outcome Measures: Absolute and relative peak torque for concentric and eccentric hamstring and quadriceps were measured at 60°/sec, 180°/sec and 240°/sec in the standardized position (hip and knee flexed at 90°). In the lengthened position (hip flexed at 85° and knee at 30°), isometric knee flexion and peak torque for concentric and eccentric hamstring and quadriceps were assessed at 60°/sec and 180°/sec. Strength ratios were calculated for both positions. Results: Intraclass Correlation Coefficient (ICC) values demonstrated good to excellent reliability for peak torque measurements, with higher reliability in the standardized position (ICC 0.83-0.94) than in the lengthened position (ICC 0.79-0.96). Conventional and functional ratios varied, with lower ICCs for the right leg in the standardized position (ICC 0.32-0.92) and moderate to good reliability in the lengthened position (ICC 0.63-0.87). Conclusion: Standardized and lengthened positions provide reliable assessments of absolute and relative peak torque for hamstring and quadriceps muscles during concentric and eccentric contractions across all speeds, including conventional and functional strength ratios.

Journal of Medicine University of Santo TomasVol. 9(1)
Openalex Percentile: Top 89%
Sports injuries and prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Test-Retest Reliability of Isokinetic Strength Measurement in Standardized and Lengthened Hamstring Positions Among Healthy Adults — Helen Banwell, Maria Belinda Cristina C. Fidel, et al. · Journal of Medicine University of Santo Tomas (2025) | TGRS Research Map | TGRS