Coil Combination Using OpTIMUS Results in Improved Signal‐to‐Noise Ratios of In Vivo MR Spectra Acquired at 7 T

Magnetic resonance spectroscopy (MRS) enables noninvasive quantification of metabolites, but its utility in vivo can be limited by low signal-to-noise ratios (SNRs) and long acquisition times. The use of ultrahigh-field (UHF) strengths (> 3 T) combined with multichannel phased receive arrays can improve spectral SNR. A crucial step in the use of multichannel arrays is the combination of spectra acquired from individual coil channels. We previously developed a coil combination method at 3 T, optimized truncation to integrate multichannel MRS data using rank-R singular value decomposition (OpTIMUS), which uses noise-whitened windowed spectra and iterative rank-R singular value decomposition (SVD) to combine multichannel MRS data. Here, we evaluated OpTIMUS for combination of MR spectra acquired using a multichannel phased array at 7 T and compared spectral SNR and metabolite quantification with spectra combined using whitened SVD (WSVD), signal/noise squared (S/N<sup>2</sup>), and the Brown method. Data were acquired from 14 healthy volunteers, including five with data acquired at both 3 and 7 T, and from nine people living with HIV. Spectra combined using OpTIMUS resulted in a higher SNR compared to the three other methods, consistent with our prior results at 3 T. With half the number of averages (N = 32), spectra combined with OpTIMUS had higher SNR compared to spectra using the Brown method with 64 averages. Additionally, spectra combined using OpTIMUS at 7 T were compared to spectra acquired at 3 T with the same number of averages (N = 64) or matched acquisition times (N = 110 averages), and spectral fitting was consistently improved at 7 T even when comparable SNR was obtained at 3 T. The ability to increase SNR and maintain spectral quality by optimizing spectral coil combination has the potential to reduce scan time, a key challenge for routine clinical use of MRS.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-04-27
DOI
https://doi.org/10.1002/nbm.70044
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coil Combination Using OpTIMUS Results in Improved Signal‐to‐Noise Ratios of In Vivo MR Spectra Acquired at 7 T

Rachel M. Goldberg, Benjamin B. Risk, Dongsuk Sung, Candace C. Fleischer et al.
1 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
1.36
article

Coil Combination Using OpTIMUS Results in Improved Signal‐to‐Noise Ratios of In Vivo MR Spectra Acquired at 7 T

Rachel M. Goldberg, Benjamin B. Risk, Dongsuk Sung, Candace C. Fleischer, Eva Martinez Luque
article en
1 citations

Abstract

Magnetic resonance spectroscopy (MRS) enables noninvasive quantification of metabolites, but its utility in vivo can be limited by low signal-to-noise ratios (SNRs) and long acquisition times. The use of ultrahigh-field (UHF) strengths (> 3 T) combined with multichannel phased receive arrays can improve spectral SNR. A crucial step in the use of multichannel arrays is the combination of spectra acquired from individual coil channels. We previously developed a coil combination method at 3 T, optimized truncation to integrate multichannel MRS data using rank-R singular value decomposition (OpTIMUS), which uses noise-whitened windowed spectra and iterative rank-R singular value decomposition (SVD) to combine multichannel MRS data. Here, we evaluated OpTIMUS for combination of MR spectra acquired using a multichannel phased array at 7 T and compared spectral SNR and metabolite quantification with spectra combined using whitened SVD (WSVD), signal/noise squared (S/N<sup>2</sup>), and the Brown method. Data were acquired from 14 healthy volunteers, including five with data acquired at both 3 and 7 T, and from nine people living with HIV. Spectra combined using OpTIMUS resulted in a higher SNR compared to the three other methods, consistent with our prior results at 3 T. With half the number of averages (N = 32), spectra combined with OpTIMUS had higher SNR compared to spectra using the Brown method with 64 averages. Additionally, spectra combined using OpTIMUS at 7 T were compared to spectra acquired at 3 T with the same number of averages (N = 64) or matched acquisition times (N = 110 averages), and spectral fitting was consistently improved at 7 T even when comparable SNR was obtained at 3 T. The ability to increase SNR and maintain spectral quality by optimizing spectral coil combination has the potential to reduce scan time, a key challenge for routine clinical use of MRS.

NMR in BiomedicineVol. 38(6)
Georgia Institute of Technology (US), Emory University (US)
Emory University, University of Minnesota, “la Caixa” Foundation, Fundación Bancaria Caixa d'Estalvis i Pensions de Barcelona, National Institutes of Health
Good health and well-being
Openalex Percentile: Top 21%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.