Performance Assessment of DC Circuit Breakers in Networks with Unpredictable Fault Current Peak Value

The DC Circuit Breaker (DCCB) is the first protective component in the DC network. On the other hand, the converters used in all DC networks are sensitive to the excess current and voltage caused by the fault. The HDCCB based on the current commutation drive circuit (CCDC) is one of the structures that provide a speedy interruption of the fault current as well as reduced losses in the pre-fault circuit while maintaining a simple structure. This structure can only be successfully interrupted at a specific rate of fault current and a specific peak of fault current, while changing the location of the fault causes a change in the peak and rate of increase of the fault current, which disrupts the interruption performance of this HDCCB. This study aims to evaluate and analyze the various structures of DCCB particularly the HDCCB based on CCDC, which is considered superior to other DCCBs. Furthermore, it emphasizes the limitations of interrupting the various peaks of fault currents using HDCCB based on CCDC, with simulated verification by Finite Element (FE). Finally, multiple proposals for further research are made to improve the performance of the CCDC structure as an ideal structure.

Authors

Institutions

Publication Details

Journal
Scientia Iranica
Published
2024-09-07
DOI
https://doi.org/10.24200/sci.2024.64249.8828
Citations
3
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Assessment of DC Circuit Breakers in Networks with Unpredictable Fault Current Peak Value

Ali A. Razi‐Kazemi, Alireza Jafari, Sadegh Mohsenzade
3 citations
Scientia Iranica
HVDC Systems and Fault Protection
0.63
article

Performance Assessment of DC Circuit Breakers in Networks with Unpredictable Fault Current Peak Value

Ali A. Razi‐Kazemi, Alireza Jafari, Sadegh Mohsenzade
article en
3 citations

Abstract

The DC Circuit Breaker (DCCB) is the first protective component in the DC network. On the other hand, the converters used in all DC networks are sensitive to the excess current and voltage caused by the fault. The HDCCB based on the current commutation drive circuit (CCDC) is one of the structures that provide a speedy interruption of the fault current as well as reduced losses in the pre-fault circuit while maintaining a simple structure. This structure can only be successfully interrupted at a specific rate of fault current and a specific peak of fault current, while changing the location of the fault causes a change in the peak and rate of increase of the fault current, which disrupts the interruption performance of this HDCCB. This study aims to evaluate and analyze the various structures of DCCB particularly the HDCCB based on CCDC, which is considered superior to other DCCBs. Furthermore, it emphasizes the limitations of interrupting the various peaks of fault currents using HDCCB based on CCDC, with simulated verification by Finite Element (FE). Finally, multiple proposals for further research are made to improve the performance of the CCDC structure as an ideal structure.

Scientia IranicaVol. 0(0)
K. N. Toosi University of Technology (IR)
Climate action
Openalex Percentile: Top 30%
HVDC Systems and Fault Protection
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.