Thoracic ultrasound in hemodialysis: Assessing fluid overload and dialysis efficacy

Fluid overload in patients with end-stage kidney disease (ESKD) usually results in pleural effusions (PEs). While volume overload remains the primary etiology of PE, other possible causes must be ruled out. Thoracic ultrasonography (TUS) is a practical and efficient method for evaluating volume in patients undergoing hemodialysis (HD), although evidence regarding its usefulness in this context is limited. We aimed to investigate the relationship between pleuropulmonary TUS patterns and overload symptoms and their correlation with optimal HD, as measured by total urea clearance (Kt/V) and the urea reduction rate (URR). This prospective longitudinal observational study included patients with ESKD who underwent renal replacement therapy with HD. Point-of-care TUS was performed before and after HD sessions. The ultrasound parameters recorded included the presence, location, sonographic patterns and volume of PE. A total of 136 patients were included in the study. TUS abnormalities compatible with interstitial syndrome (B-lines) were identified in 56 (41%) patients. Forty-four patients (32%) had PE. The PE volume showed a statistically significant decrease after HD and normalized in 12% of the patients. No significant difference in the proportion of patients who achieved a URR > 65 or optimal Kt/V was observed between patients with abnormal (B-lines) and normal TUS results (P = .39). The presence of PE and B-lines was significantly associated with overload symptoms; however, these overload symptoms were not related to optimal HD, as measured by the Kt/V or URR. PE and B-lines demonstrated a stronger association with overload symptoms than Kt/V or URR in HD patients. No relationship was found between the TUS pleuropulmonary changes and HD efficacy.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-04-25
DOI
https://doi.org/10.1097/md.0000000000042023
Citations
1
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thoracic ultrasound in hemodialysis: Assessing fluid overload and dialysis efficacy

José M. Porcel, Julio E. González-Aguirre, Roberto Mercado-Longoría, Homero Náñez-Terreros et al.
1 citations
Medicine
Ultrasound in Clinical Applications
1.55
article

Thoracic ultrasound in hemodialysis: Assessing fluid overload and dialysis efficacy

José M. Porcel, Julio E. González-Aguirre, Roberto Mercado-Longoría, Homero Náñez-Terreros, J González-Garza, Mara Cecilia Olivo Gutiérrez, Héctor Alejandro Vaquera Alfaro, Ricardo César Solís, Perla R. Colunga‐Pedraza, Erick Joel Rendón-Ramírez, Samantha B. Medrano Juárez, Elva Alejandra Manjarrez-Granados, Natalia Alvarez-Martinez
article en
1 citations

Abstract

Fluid overload in patients with end-stage kidney disease (ESKD) usually results in pleural effusions (PEs). While volume overload remains the primary etiology of PE, other possible causes must be ruled out. Thoracic ultrasonography (TUS) is a practical and efficient method for evaluating volume in patients undergoing hemodialysis (HD), although evidence regarding its usefulness in this context is limited. We aimed to investigate the relationship between pleuropulmonary TUS patterns and overload symptoms and their correlation with optimal HD, as measured by total urea clearance (Kt/V) and the urea reduction rate (URR). This prospective longitudinal observational study included patients with ESKD who underwent renal replacement therapy with HD. Point-of-care TUS was performed before and after HD sessions. The ultrasound parameters recorded included the presence, location, sonographic patterns and volume of PE. A total of 136 patients were included in the study. TUS abnormalities compatible with interstitial syndrome (B-lines) were identified in 56 (41%) patients. Forty-four patients (32%) had PE. The PE volume showed a statistically significant decrease after HD and normalized in 12% of the patients. No significant difference in the proportion of patients who achieved a URR > 65 or optimal Kt/V was observed between patients with abnormal (B-lines) and normal TUS results (P = .39). The presence of PE and B-lines was significantly associated with overload symptoms; however, these overload symptoms were not related to optimal HD, as measured by the Kt/V or URR. PE and B-lines demonstrated a stronger association with overload symptoms than Kt/V or URR in HD patients. No relationship was found between the TUS pleuropulmonary changes and HD efficacy.

MedicineVol. 104(17)
Universitat de Lleida (ES), Universidad Autónoma de Nuevo León (MX), Hospital Universitari Arnau de Vilanova (ES), Hospital Universitario Dr José Eleuterio Gonzalez (MX), Instituto de Investigación Biomédica de Lleida (ES)
Good health and well-being
Openalex Percentile: Top 20%
Ultrasound in Clinical Applications
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.