A systematic characterization of plastic scintillation dosimeters response in magnetic fields: II. Monte Carlo simulations

<i>Purpose.</i>This study aims to investigate and validate the response of plastic scintillation dosimeters (PSDs) in the presence of magnetic fields using Monte Carlo simulations, focusing on the accuracy of electron fluence, dose calculations, and the optical processes of scintillation and Cherenkov radiation.<i>Methods.</i>Monte Carlo simulations, using EGSnrc and TOPAS, of the PSD response under magnetic fields were performed. First, electron fluence simulations were conducted with three different physics listsg4em-penelope,g4em-standard_opt3andg4em-standard_opt4, with the goal of benchmarking their performance in magnetic fields. Secondly, a Fano test for dose calculations was performed using only theg4em-penelopephysics list. Thirdly, the Cherenkov process under magnetic fields was validated against theoretical predictions. Finally, a PSD probe was modeled and simulated, with results compared against measurements.<i>Results.</i>Theg4em-penelopephysics list demonstrated a most balanced performance, showing the closest agreement with EGSnrc simulations and lower variability in magnetic fields thang4em-standard_opt4. Fano test results showed an accuracy of at least 0.36% for dose calculations. Simulations of Cherenkov radiation in ideal conditions were in agreement with theoretical predictions at both 0 T and 1.5 T. Monte Carlo simulations successfully reproduced experimental trends for Cherenkov radiation under magnetic fields. However, discrepancies were found, with deviations of up to 7.7% when electrons were deflected towards the tip and up to 21.0% in the opposite direction, likely due to modeling limitations. A key result is that Monte Carlo simulations of the scintillation process in magnetic fields failed to reproduce experimental observations. While experimental results showed a significant effect of magnetic fields on scintillation yield, the simulations did not reflect this behavior.<i>Conclusion.</i>This study establishes that TOPAS, specifically using theg4em-penelopephysics list, is a reliable tool for simulating dose, electron fluence, and Cherenkov radiation in the presence of magnetic fields. However, significant discrepancies were observed in the scintillation processes, where Monte Carlo simulations failed to reproduce the effect of magnetic fields seen in experimental measurements. These findings point out the need for further refinement of simulation models, particularly in accurately representing scintillation under magnetic fields.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-04-28
DOI
https://doi.org/10.1088/1361-6560/add1a8
Citations
1
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
1.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A systematic characterization of plastic scintillation dosimeters response in magnetic fields: II. Monte Carlo simulations

François Therriault‐Proulx, Simon Lambert‐Girard, Ilias Billas, Luc Beaulieu et al.
1 citations
Physics in Medicine and Biology
Radiation Effects and Dosimetry
1.16
article

A systematic characterization of plastic scintillation dosimeters response in magnetic fields: II. Monte Carlo simulations

François Therriault‐Proulx, Simon Lambert‐Girard, Ilias Billas, Luc Beaulieu, Yunuen Cervantes, Hugo Bouchard, Louis Archambault
article en
1 citations

Abstract

<i>Purpose.</i>This study aims to investigate and validate the response of plastic scintillation dosimeters (PSDs) in the presence of magnetic fields using Monte Carlo simulations, focusing on the accuracy of electron fluence, dose calculations, and the optical processes of scintillation and Cherenkov radiation.<i>Methods.</i>Monte Carlo simulations, using EGSnrc and TOPAS, of the PSD response under magnetic fields were performed. First, electron fluence simulations were conducted with three different physics listsg4em-penelope,g4em-standard_opt3andg4em-standard_opt4, with the goal of benchmarking their performance in magnetic fields. Secondly, a Fano test for dose calculations was performed using only theg4em-penelopephysics list. Thirdly, the Cherenkov process under magnetic fields was validated against theoretical predictions. Finally, a PSD probe was modeled and simulated, with results compared against measurements.<i>Results.</i>Theg4em-penelopephysics list demonstrated a most balanced performance, showing the closest agreement with EGSnrc simulations and lower variability in magnetic fields thang4em-standard_opt4. Fano test results showed an accuracy of at least 0.36% for dose calculations. Simulations of Cherenkov radiation in ideal conditions were in agreement with theoretical predictions at both 0 T and 1.5 T. Monte Carlo simulations successfully reproduced experimental trends for Cherenkov radiation under magnetic fields. However, discrepancies were found, with deviations of up to 7.7% when electrons were deflected towards the tip and up to 21.0% in the opposite direction, likely due to modeling limitations. A key result is that Monte Carlo simulations of the scintillation process in magnetic fields failed to reproduce experimental observations. While experimental results showed a significant effect of magnetic fields on scintillation yield, the simulations did not reflect this behavior.<i>Conclusion.</i>This study establishes that TOPAS, specifically using theg4em-penelopephysics list, is a reliable tool for simulating dose, electron fluence, and Cherenkov radiation in the presence of magnetic fields. However, significant discrepancies were observed in the scintillation processes, where Monte Carlo simulations failed to reproduce the effect of magnetic fields seen in experimental measurements. These findings point out the need for further refinement of simulation models, particularly in accurately representing scintillation under magnetic fields.

Physics in Medicine and BiologyVol. 70(10)
Natural Sciences and Engineering Research Council of Canada (CA), Héma-Québec (CA), National Physical Laboratory (GB), Université du Québec à Montréal (CA), Rio Tinto (Canada) (CA), Hôtel-Dieu de Québec (CA), Centre Hospitalier de l’Université de Montréal (CA), Université Laval (CA), Université de Montréal (CA)
Mitacs, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 23%
Radiation Effects and Dosimetry
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.