Optimization of electric vehicle charging facility layout considering the enhancement of renewable energy consumption capacity and improvement of PSO algorithm

By arranging the charging facilities of electric vehicles reasonably, electric vehicle users can be guided to charge during the peak period of renewable energy generation, improving their ability to consume this energy. To layout electric vehicle charging facilities, a single charging station optimization configuration model is constructed to provide optimal configuration parameter references for subsequent charging facility layout optimization models. In the optimization model, the study considers charging load calculation, site selection, and capacity determination. To deal with the optimization model, the particle swarm optimization is adopted and improved in three aspects. These three improvements include randomly updating inertia weights, introducing acceleration factors to replace learning factors, and introducing fast non-dominated sorting for better or worse selection, and improving the optimization ability of the algorithm by solving the crowding distance. The results showed that the maximum function values of the designed algorithm were 3.56 × 10–14, 5.32 × 100, and 1.08 × 101 for unimodal, multimodal, and composite functions, respectively, and the standard deviations of the algorithm were 2.01 × 10–14, 3.557 × 100, and 8.56 × 10–1, all of which were smaller than comparison algorithms. In a single charging station, the expected values of photovoltaic power generation, energy storage system, and charging piles were 500 kW, 56.45 kW/20163 kW, and 680 kW, respectively. In terms of charging station location and charging facility capacity, there should be 7 charging locations and charging facilities. In summary, the designed model has good performance, and the optimized model can layout charging facilities. The research results can better promote the consumption of renewable energy, lower the construction cost, and optimize the utilization rate of charging facilities.

Authors

Institutions

Publication Details

Journal
Energy Informatics
Published
2025-04-28
DOI
https://doi.org/10.1186/s42162-025-00514-8
Citations
4
Primary Topic
Electric Vehicles and Infrastructure
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of electric vehicle charging facility layout considering the enhancement of renewable energy consumption capacity and improvement of PSO algorithm

Bingyong Zheng, Di Zheng
4 citations
Energy Informatics
Electric Vehicles and Infrastructure
2.92
article

Optimization of electric vehicle charging facility layout considering the enhancement of renewable energy consumption capacity and improvement of PSO algorithm

Bingyong Zheng, Di Zheng
article en
4 citations

Abstract

By arranging the charging facilities of electric vehicles reasonably, electric vehicle users can be guided to charge during the peak period of renewable energy generation, improving their ability to consume this energy. To layout electric vehicle charging facilities, a single charging station optimization configuration model is constructed to provide optimal configuration parameter references for subsequent charging facility layout optimization models. In the optimization model, the study considers charging load calculation, site selection, and capacity determination. To deal with the optimization model, the particle swarm optimization is adopted and improved in three aspects. These three improvements include randomly updating inertia weights, introducing acceleration factors to replace learning factors, and introducing fast non-dominated sorting for better or worse selection, and improving the optimization ability of the algorithm by solving the crowding distance. The results showed that the maximum function values of the designed algorithm were 3.56 × 10–14, 5.32 × 100, and 1.08 × 101 for unimodal, multimodal, and composite functions, respectively, and the standard deviations of the algorithm were 2.01 × 10–14, 3.557 × 100, and 8.56 × 10–1, all of which were smaller than comparison algorithms. In a single charging station, the expected values of photovoltaic power generation, energy storage system, and charging piles were 500 kW, 56.45 kW/20163 kW, and 680 kW, respectively. In terms of charging station location and charging facility capacity, there should be 7 charging locations and charging facilities. In summary, the designed model has good performance, and the optimized model can layout charging facilities. The research results can better promote the consumption of renewable energy, lower the construction cost, and optimize the utilization rate of charging facilities.

Energy InformaticsVol. 8(1)
Xinyang Agriculture and Forestry University (CN)
Affordable and clean energy
Openalex Percentile: Top 9%
Electric Vehicles and Infrastructure
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of electric vehicle charging facility layout considering the enhancement of renewable energy consumption capacity and improvement of PSO algorithm — Bingyong Zheng, Di Zheng · Energy Informatics (2025) | TGRS Research Map | TGRS