Analysis of a Steel Frame Structure in Loess Area for Correcting Deflection and Stopping Tilting Reinforcement
Currently, Surface water infiltration saturates the soil layer of the building foundation, is causing uneven settlement of the pile foundation of the building, resulting in obvious tilting and deformation of the upper main structure. The primary objective of this study is to taking the corrective and stop-tilting reinforcement of a steel frame structure in the humid loess area as the research background, the existing pile foundation is corrected and strengthened by adopting grouted flower steel pipe piles, and the analytical results show that the settlement and deformation of the foundation after grouted flower steel pipe piles reinforcement reduces from 50.3% to 92.83%. This method achieves the purpose of correcting deflection and stopping tilting reinforcement, and meets the bearing capacity requirements of the foundation of the building, and the construction is convenient.
Authors
- Guobing Wang (ORCID: https://orcid.org/0000-0001-8362-9186)
- Dongwu Yang (ORCID: https://orcid.org/0000-0002-4961-3006)
- Shengjun Dong
Publication Details
- Journal
- Journal of civil and transportation engineering.
- Published
- 2024-09-01
- DOI
- https://doi.org/10.62517/jcte.202406301
- Primary Topic
- Structural Load-Bearing Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00