A Comparative Analysis of Advanced Glazing Technologies for Energy-Efficient Buildings in Jeddah City, Saudi Arabia

This study employs Design Builder software to evaluate advanced glazing technologies for enhancing the thermal performance of residential buildings in Jeddah, Saudi Arabia. Recognizing the energy inefficiencies caused by adopting Western architectural styles unsuited to local climatic conditions, and given that buildings consume 44% of national energy, we conducted a systematic parametric analysis to isolate the effects of key glazing parameters. The study examines six polycarbonate (PC) configurations and three critical comparative cases: (1) a selective double-glazed unit representing a new baseline glazing; (2) a low-U configuration to isolate thermal insulation effects; and (3) a low-SHGC configuration to evaluate solar heat gain mitigation independently. These controlled comparisons address a critical research gap by decoupling the traditionally confounded impacts of U-value and SHGC in hot climates. The simulations reveal that the 36 mm aerogel glazing (U = 0.9 W/m2·K, SHGC = 0.3) reduces cooling demand by 48.6% annually compared to single-pane glazing while maintaining indoor temperatures at 30.09 °C versus 38.43 °C at baseline. Notably, the findings demonstrate that 87% of these savings derive from SHGC reduction, with only 3.02 percentage points attributable to U-value improvements. The selective DGU benchmark delivers 85% of aerogel’s benefits at 40% lower cost, establishing it as a practical solution for most applications. These findings provide evidence-based guidance for Saudi Vision 2030’s sustainability goals, emphasizing that while aerogel glazing excels in extreme solar exposures, strategic SHGC optimization in conventional glazing can achieve the most energy savings in hot climates.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-04-26
DOI
https://doi.org/10.3390/buildings15091477
Citations
4
Primary Topic
Aerogels and thermal insulation
Type
article
Field-Weighted Citation Impact
3.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Analysis of Advanced Glazing Technologies for Energy-Efficient Buildings in Jeddah City, Saudi Arabia

Amr Sayed Hassan Abdallah, Ayman Ragab, Mohammed M. Gomaa, Mohammed A. Aloshan
4 citations
Buildings
Aerogels and thermal insulation
3.03
article

A Comparative Analysis of Advanced Glazing Technologies for Energy-Efficient Buildings in Jeddah City, Saudi Arabia

Amr Sayed Hassan Abdallah, Ayman Ragab, Mohammed M. Gomaa, Mohammed A. Aloshan
article en
4 citations

Abstract

This study employs Design Builder software to evaluate advanced glazing technologies for enhancing the thermal performance of residential buildings in Jeddah, Saudi Arabia. Recognizing the energy inefficiencies caused by adopting Western architectural styles unsuited to local climatic conditions, and given that buildings consume 44% of national energy, we conducted a systematic parametric analysis to isolate the effects of key glazing parameters. The study examines six polycarbonate (PC) configurations and three critical comparative cases: (1) a selective double-glazed unit representing a new baseline glazing; (2) a low-U configuration to isolate thermal insulation effects; and (3) a low-SHGC configuration to evaluate solar heat gain mitigation independently. These controlled comparisons address a critical research gap by decoupling the traditionally confounded impacts of U-value and SHGC in hot climates. The simulations reveal that the 36 mm aerogel glazing (U = 0.9 W/m2·K, SHGC = 0.3) reduces cooling demand by 48.6% annually compared to single-pane glazing while maintaining indoor temperatures at 30.09 °C versus 38.43 °C at baseline. Notably, the findings demonstrate that 87% of these savings derive from SHGC reduction, with only 3.02 percentage points attributable to U-value improvements. The selective DGU benchmark delivers 85% of aerogel’s benefits at 40% lower cost, establishing it as a practical solution for most applications. These findings provide evidence-based guidance for Saudi Vision 2030’s sustainability goals, emphasizing that while aerogel glazing excels in extreme solar exposures, strategic SHGC optimization in conventional glazing can achieve the most energy savings in hot climates.

BuildingsVol. 15(9)
Imam Mohammad ibn Saud Islamic University (SA), Dar Al-Hekma University (SA), Aswan University (EG)
Al-Imam Muhammad Ibn Saud Islamic University
Openalex Percentile: Top 9%
Aerogels and thermal insulation
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.