Ready-to-Use OECT Biosensor toward Rapid and Real-Time Protein Detection in Complex Biological Environments

Organic electrochemical transistor (OECT) sensors are a promising approach for point-of-care testing (POCT) thanks to their high sensitivity and ability to operate in an aqueous environment. However, OECTs suffer from biological fouling at the gate and channel interfaces when exposed to complex biological samples. These nonspecific interactions can often obscure the weak signal from the trace biomarker, compromising the accuracy and sensitivity of measurements and even leading to false detection outcomes. In this study, we developed an intrinsically antifouling OECT by modifying both the gate and channel with phosphorylcholine-functionalized poly(3,4-ethylenedioxythiophene) (PEDOT-PC). This modification notably enhances the OECT performance by leveraging the material's inherent mixed electron-ion conductivity, which increases transconductance and decreases gate voltage. Additionally, the zwitterionic nature of the device enables its ultrasensitive detection of C-reactive protein (CRP) with a limit of detection of 0.11 pg/mL, mediated by calcium ions. This exceptional sensitivity arises from the device's enhanced transconductance and ability to sense through the gate and channel interfaces simultaneously. Furthermore, the zwitterionic OECT sensor has demonstrated the fastest sample-to-result time for protein detection (≤60 s), making it highly suitable for real-time CRP monitoring. Importantly, it provides precise real-time detection of CRP without interference from nonspecific proteins such as bovine serum albumin, fibrinogen, lysozyme, and fetal bovine serum. We envision this intrinsically antifouling OECT device offering a robust biosensing platform for the rapid and convenient detection of biomarkers in complex biological environments, providing a reliable and efficient solution for POCT diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-04-28
DOI
https://doi.org/10.1021/acssensors.4c03072
Citations
16
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
9.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ready-to-Use OECT Biosensor toward Rapid and Real-Time Protein Detection in Complex Biological Environments

Zhi Geng, Chunyang Xia, Bo Zhu, Arzum Erdem et al.
16 citations
ACS Sensors
Conducting polymers and applications
9.71
article

Ready-to-Use OECT Biosensor toward Rapid and Real-Time Protein Detection in Complex Biological Environments

Zhi Geng, Chunyang Xia, Bo Zhu, Arzum Erdem, Ke Tang, Jun Wang, Shu‐Hua Zhang, Shouyan Zhang, Shixiong Chen, Yixuan Wang
article en
16 citations

Abstract

Organic electrochemical transistor (OECT) sensors are a promising approach for point-of-care testing (POCT) thanks to their high sensitivity and ability to operate in an aqueous environment. However, OECTs suffer from biological fouling at the gate and channel interfaces when exposed to complex biological samples. These nonspecific interactions can often obscure the weak signal from the trace biomarker, compromising the accuracy and sensitivity of measurements and even leading to false detection outcomes. In this study, we developed an intrinsically antifouling OECT by modifying both the gate and channel with phosphorylcholine-functionalized poly(3,4-ethylenedioxythiophene) (PEDOT-PC). This modification notably enhances the OECT performance by leveraging the material's inherent mixed electron-ion conductivity, which increases transconductance and decreases gate voltage. Additionally, the zwitterionic nature of the device enables its ultrasensitive detection of C-reactive protein (CRP) with a limit of detection of 0.11 pg/mL, mediated by calcium ions. This exceptional sensitivity arises from the device's enhanced transconductance and ability to sense through the gate and channel interfaces simultaneously. Furthermore, the zwitterionic OECT sensor has demonstrated the fastest sample-to-result time for protein detection (≤60 s), making it highly suitable for real-time CRP monitoring. Importantly, it provides precise real-time detection of CRP without interference from nonspecific proteins such as bovine serum albumin, fibrinogen, lysozyme, and fetal bovine serum. We envision this intrinsically antifouling OECT device offering a robust biosensing platform for the rapid and convenient detection of biomarkers in complex biological environments, providing a reliable and efficient solution for POCT diagnostics.

ACS SensorsVol. 10(5)
Shanghai University (CN), Ministry of Education of the People's Republic of China (CN), Ege University (TR)
National Natural Science Foundation of China
Openalex Percentile: Top 1%
Conducting polymers and applications
9.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.