Flow Characteristics Effect on Different Blades Number of Radial Fan

Radial fans are mainly used in industrial applications where working efficiency is of paramount importance. In order to examine the mass flow rate at the outlet for various configurations, three radial fan models with 12, 16, and 20 blades were modeled using ANSYS Fluent. The mass flow rate at the outlet of the 12-blade radial fan was determined to be 0.15897 kg/s. The mass flow rates for the 16-blade and 20-blade radial fans were 0.22092 kg/s and 0.22309 kg/s respectively, thus showing an increase in performance. The hypothesis of this study is therefore confirmed by the fact that as the number of blades increases, the spacing between them reduces ; hence, fluid flows at greater velocities, thereby enhancing the mass-flow rates. Verification and validation were established by comparing the results with those of other studies, which revealed a reasonable percentage error in each case. Furthermore, at the blade tips of the radial fan, the high static pressure, in conjunction with the radial velocity, reduces the vibration rates.

Authors

Institutions

Publication Details

Journal
Semarak Journal of Thermal Fluid Engineering
Published
2025-04-25
DOI
https://doi.org/10.37934/sjotfe.2.1.18a
Citations
1
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow Characteristics Effect on Different Blades Number of Radial Fan

Ishkrizat Taib, K.W. Chan, Xin Yi Wong
1 citations
Semarak Journal of Thermal Fluid Engineering
Heat Transfer Mechanisms
0.71
article

Flow Characteristics Effect on Different Blades Number of Radial Fan

Ishkrizat Taib, K.W. Chan, Xin Yi Wong
article en
1 citations

Abstract

Radial fans are mainly used in industrial applications where working efficiency is of paramount importance. In order to examine the mass flow rate at the outlet for various configurations, three radial fan models with 12, 16, and 20 blades were modeled using ANSYS Fluent. The mass flow rate at the outlet of the 12-blade radial fan was determined to be 0.15897 kg/s. The mass flow rates for the 16-blade and 20-blade radial fans were 0.22092 kg/s and 0.22309 kg/s respectively, thus showing an increase in performance. The hypothesis of this study is therefore confirmed by the fact that as the number of blades increases, the spacing between them reduces ; hence, fluid flows at greater velocities, thereby enhancing the mass-flow rates. Verification and validation were established by comparing the results with those of other studies, which revealed a reasonable percentage error in each case. Furthermore, at the blade tips of the radial fan, the high static pressure, in conjunction with the radial velocity, reduces the vibration rates.

Semarak Journal of Thermal Fluid EngineeringVol. 2(1)
Tun Hussein Onn University of Malaysia (MY)
Universiti Tun Hussein Onn Malaysia
Openalex Percentile: Top 33%
Heat Transfer Mechanisms
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Flow Characteristics Effect on Different Blades Number of Radial Fan — Ishkrizat Taib, K.W. Chan, et al. · Semarak Journal of Thermal Fluid Engineering (2025) | TGRS Research Map | TGRS