In situ microscopy and electrochemical characteristics of initiation of intergranular corrosion of aging-treated Al–1Mg–0.65Si–0.8Cu alloy in 0.1 M NaCl

This study investigated the initiation site of intergranular corrosion (IGC) in aging-treated Al–1Mg–0.65Si–0.8Cu alloy in 0.1 M NaCl. Polarization and open-circuit potential measurements were performed. Further, in situ observations were made using a small electrode area of 300 µm × 300 µm. In potentiodynamic polarization, the breakdown potential was −0.4 V vs. SHE, leading to pitting corrosion, which in turn initiated IGC. The OCP under naturally aerated conditions increased from approximately −1.2 to −0.4 V over time, and IGC was initiated at −0.4 V. Even in the case of the small electrode area (300 µm × 300 µm), IGC occurred at −0.4 V in potentiostatic polarization; high-spatial-resolution in situ observations were then performed. IGC initiated from randomly distributed Mg 2 Si particles and generation of gas bubbles. Moreover, the Mg 2 Si particles at the initiation site of IGC were located on or near the grain boundaries, and trenching was observed at the Mg 2 Si/alloy matrix boundaries. In addition to the exposure of the bare alloy surface by trenching, the acidification inside the trench likely contributed to the initiation of IGC. The role of Mg 2 Si in the initiation of IGC was examined based on the results of in situ observations and the polarization behavior. • Mg 2 Si particles (≥1 µm) were randomly distributed in Al–1Mg–0.65Si–0.8Cu alloy. • Intergranular corrosion (IGC) initiated at Mg 2 Si located on or near grain boundary. • Trenching between Mg 2 Si and alloy matrix provided the sites for IGC. • An acid in the trench likely dissolves the Cu-depleted zone and leads to IGC. • Corrosion tunnels around the Mg 2 Si might also be related to the IGC initiation.

Authors

Institutions

Publication Details

Journal
Corrosion Science
Published
2025-04-27
DOI
https://doi.org/10.1016/j.corsci.2025.112985
Citations
6
Primary Topic
Aluminum Alloy Microstructure Properties
Type
article
Field-Weighted Citation Impact
29.96

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In situ microscopy and electrochemical characteristics of initiation of intergranular corrosion of aging-treated Al–1Mg–0.65Si–0.8Cu alloy in 0.1 M NaCl

Masashi Nishimoto, Izumi Muto, Mai Takaya, M. Inagaki
6 citations
Corrosion Science
Aluminum Alloy Microstructure Properties
29.96
article

In situ microscopy and electrochemical characteristics of initiation of intergranular corrosion of aging-treated Al–1Mg–0.65Si–0.8Cu alloy in 0.1 M NaCl

Masashi Nishimoto, Izumi Muto, Mai Takaya, M. Inagaki
article en
6 citations

Abstract

This study investigated the initiation site of intergranular corrosion (IGC) in aging-treated Al–1Mg–0.65Si–0.8Cu alloy in 0.1 M NaCl. Polarization and open-circuit potential measurements were performed. Further, in situ observations were made using a small electrode area of 300 µm × 300 µm. In potentiodynamic polarization, the breakdown potential was −0.4 V vs. SHE, leading to pitting corrosion, which in turn initiated IGC. The OCP under naturally aerated conditions increased from approximately −1.2 to −0.4 V over time, and IGC was initiated at −0.4 V. Even in the case of the small electrode area (300 µm × 300 µm), IGC occurred at −0.4 V in potentiostatic polarization; high-spatial-resolution in situ observations were then performed. IGC initiated from randomly distributed Mg 2 Si particles and generation of gas bubbles. Moreover, the Mg 2 Si particles at the initiation site of IGC were located on or near the grain boundaries, and trenching was observed at the Mg 2 Si/alloy matrix boundaries. In addition to the exposure of the bare alloy surface by trenching, the acidification inside the trench likely contributed to the initiation of IGC. The role of Mg 2 Si in the initiation of IGC was examined based on the results of in situ observations and the polarization behavior. • Mg 2 Si particles (≥1 µm) were randomly distributed in Al–1Mg–0.65Si–0.8Cu alloy. • Intergranular corrosion (IGC) initiated at Mg 2 Si located on or near grain boundary. • Trenching between Mg 2 Si and alloy matrix provided the sites for IGC. • An acid in the trench likely dissolves the Cu-depleted zone and leads to IGC. • Corrosion tunnels around the Mg 2 Si might also be related to the IGC initiation.

Corrosion ScienceVol. 252
Development Bank of Japan (JP), Tohoku University (JP)
Light Metals Educational Foundation, Light Metal Educational Foundation, Japan Society for the Promotion of Science
Openalex Percentile: Top 1%
Aluminum Alloy Microstructure Properties
29.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.