Analisis Fisika, Kimia, dan Biologi Sampel Air Minum Pancuran

In this research, the main objective to determine the number of Coliform bacteria, pH, temperature and TSS found in shower water samples in Lora Village. The results of testing the physical properties of water represented by TSS exceed the quality standards with an average value of 313.33 mg/l. Meanwhile, the water temperature is still in accordance with quality standards, namely 2°C from environmental temperature. The chemical properties represented by pH show a value of 7, and the biological properties of the water sample, namely total coliforms of 29 jml/100 ml, this value is still in accordance with the quality standards according to PERMENKES No. 2 of 2023 concerning environmental health quality standards and water health requirements for hygienic and sanitation purposes. From the test results it can be concluded that the total coliform, pH and temperature tests still comply with quality standards. Meanwhile, TSS passes quality standards.

Authors

Publication Details

Journal
Jurnal TELUK Teknik Lingkungan UM Kendari
Published
2024-12-30
DOI
https://doi.org/10.51454/teluk.v4i2.718
Primary Topic
Heavy Metal Pollution Remediation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Fisika, Kimia, dan Biologi Sampel Air Minum Pancuran

Rosdiana Rosdiana, Aryani Adami, Irzalin Irzalin
Jurnal TELUK Teknik Lingkungan UM Kendari
Heavy Metal Pollution Remediation
article

Analisis Fisika, Kimia, dan Biologi Sampel Air Minum Pancuran

Rosdiana Rosdiana, Aryani Adami, Irzalin Irzalin
article en

Abstract

In this research, the main objective to determine the number of Coliform bacteria, pH, temperature and TSS found in shower water samples in Lora Village. The results of testing the physical properties of water represented by TSS exceed the quality standards with an average value of 313.33 mg/l. Meanwhile, the water temperature is still in accordance with quality standards, namely 2°C from environmental temperature. The chemical properties represented by pH show a value of 7, and the biological properties of the water sample, namely total coliforms of 29 jml/100 ml, this value is still in accordance with the quality standards according to PERMENKES No. 2 of 2023 concerning environmental health quality standards and water health requirements for hygienic and sanitation purposes. From the test results it can be concluded that the total coliform, pH and temperature tests still comply with quality standards. Meanwhile, TSS passes quality standards.

Jurnal TELUK Teknik Lingkungan UM KendariVol. 4(2)
Openalex Percentile: Top 72%
Heavy Metal Pollution Remediation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.