ANALISA KEKUATAN STRUKTUR WALKING BEAM PADA SUCKER ROD PUMP MENGGUNAKAN METODE SIMULASI NUMERIK FINITE ELEMENT ANALYSIS

Sucker Rod Pump are a technology that has been used for a long time in the petroleum mining industry and proven effective in lifting oil from wells that have low flow rates. One of the companies in Indonesia which still produces Sucker Rod Pump is PT. Bukaka Engineering Utama Tbk. Sucker Rod Pump is a tool that used to raise petroleum from the well to the ground surface. In a Sucker Rod Pump there are several main components, namely the Walking Beam, Horse Head, Samson Post, Crank, Counter Weight, Pitman, Equalizer, Gear Box, electric motor and V-Belt. Walking Beam is a very component has a big influence on the performance of the Pumping Unit, in this case Walking The beam on the Pumping Unit must be appropriate in terms of strength, durability and... security, this is intended to obtain effective, maximum performance. On During the design process, the Walking Beam was designed using software solidworks 2024. The material used is ASTM A36 Steel Plate, with dimensions 5000mm long, 617mm high and 200mm wide. This Walking Beam analyzed using Solidworks 2024 Software. In the Von Misses stress test, it is obtained The maximum stress result is 76,756 MPa. While the minimum voltage found on the base plate is 0.222 Mpa. For the results of the simulation The maximum displacement value obtained is 2,550 mm for color red and a minimum displacement of 41.498 mm which is indicated by blue. Lastly, safety factor testing was carried out where the results were obtained The maximum safety factor is 1,126.43 on the base plate. Meanwhile numbers The minimum security is in the blue section, namely 0.003. From the results analysis obtained, it can be seen that the Walking Beam was used it's not safe. In the analysis process the author only uses value obtained from calculating the lifting force, object mass, well volume, and the weight of the load used (ignoring the weight of the Equlizer, Pitman, Crank, and power from the gear reducer). This is done to find out what are the conditions when the Walking Beam is operating to lift fluid from At the bottom of the well then there was a problem with the drive motor.

Authors

Institutions

Publication Details

Journal
Rekayasa Mekanika/Rekayasa mekanik : jurnal ilmiah teknik mesin
Published
2025-04-16
DOI
https://doi.org/10.33369/rekayasamekanika.v9i1.40639
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISA KEKUATAN STRUKTUR WALKING BEAM PADA SUCKER ROD PUMP MENGGUNAKAN METODE SIMULASI NUMERIK FINITE ELEMENT ANALYSIS

Nanda Nanda, Afdhal Kurniawan Mainil Mainil, Nurul Iman Supardi, Alben Sindhu Winata
Rekayasa Mekanika/Rekayasa mekanik : jurnal ilmiah teknik mesin
Oil and Gas Production Techniques
article

ANALISA KEKUATAN STRUKTUR WALKING BEAM PADA SUCKER ROD PUMP MENGGUNAKAN METODE SIMULASI NUMERIK FINITE ELEMENT ANALYSIS

Nanda Nanda, Afdhal Kurniawan Mainil Mainil, Nurul Iman Supardi, Alben Sindhu Winata
article en

Abstract

Sucker Rod Pump are a technology that has been used for a long time in the petroleum mining industry and proven effective in lifting oil from wells that have low flow rates. One of the companies in Indonesia which still produces Sucker Rod Pump is PT. Bukaka Engineering Utama Tbk. Sucker Rod Pump is a tool that used to raise petroleum from the well to the ground surface. In a Sucker Rod Pump there are several main components, namely the Walking Beam, Horse Head, Samson Post, Crank, Counter Weight, Pitman, Equalizer, Gear Box, electric motor and V-Belt. Walking Beam is a very component has a big influence on the performance of the Pumping Unit, in this case Walking The beam on the Pumping Unit must be appropriate in terms of strength, durability and... security, this is intended to obtain effective, maximum performance. On During the design process, the Walking Beam was designed using software solidworks 2024. The material used is ASTM A36 Steel Plate, with dimensions 5000mm long, 617mm high and 200mm wide. This Walking Beam analyzed using Solidworks 2024 Software. In the Von Misses stress test, it is obtained The maximum stress result is 76,756 MPa. While the minimum voltage found on the base plate is 0.222 Mpa. For the results of the simulation The maximum displacement value obtained is 2,550 mm for color red and a minimum displacement of 41.498 mm which is indicated by blue. Lastly, safety factor testing was carried out where the results were obtained The maximum safety factor is 1,126.43 on the base plate. Meanwhile numbers The minimum security is in the blue section, namely 0.003. From the results analysis obtained, it can be seen that the Walking Beam was used it's not safe. In the analysis process the author only uses value obtained from calculating the lifting force, object mass, well volume, and the weight of the load used (ignoring the weight of the Equlizer, Pitman, Crank, and power from the gear reducer). This is done to find out what are the conditions when the Walking Beam is operating to lift fluid from At the bottom of the well then there was a problem with the drive motor.

Rekayasa Mekanika/Rekayasa mekanik : jurnal ilmiah teknik mesinVol. 9(1)
Universitas Dehasen Bengkulu (ID), Universitas Teknologi Yogyakarta (ID), University of Bengkulu (ID)
Openalex Percentile: Top 89%
Oil and Gas Production Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.