Study on mechanical properties of hollow square steel composite columns embedded steel fiber ceramsite concrete

Abstract In the evolving landscape of structural engineering, concrete‐filled double skinned tubes (CFDST) attract attention due to their enhanced bearing capacities and deformation capabilities, pivotal for seismic and fire resistance. This study explores the structural behavior and mechanical performance of hollow square steel composite columns embedded with steel fiber‐reinforced ceramsite concrete, in contrast to conventional solid steel tube concrete (CFST) columns with equivalent material composition and external dimensions. The experimental program includes axial and eccentric compression tests on a series of nine CFDST specimens and one CFST specimen. The manipulated parameters include the ceramsite aggregate replacement rate (0%, 50%, 100%), hollow ratio (0, 0.22, 0.42), and eccentricity (0, 30, 50 mm). The documentation of failure modes meticulously highlights shear failure and drum‐like wrinkling in axially loaded specimens at ultimate loads, along with concrete crushing on the compression side accompanied by tension‐side cracking in eccentrically loaded setups. Analysis reveals that the ultimate bearing capacities of CFDST specimens exceed those of their CFST counterparts, with the highest recorded at 1726 kN for axially compressed columns, and decrease progressively with increased hollow ratios and eccentricities. Notably, the study establishes that increasing the ceramsite replacement rate adversely affects the ultimate bearing capacity, illustrating a decrement trend with higher aggregate replacement rates, where the maximum bearing decrease is observed in specimens with a 100% replacement rate, achieving only 1521 kN. The study identifies a significant enhancement in the ductility coefficients of CFDST specimens over traditional CFST designs, underscoring the beneficial integration of steel fibers and optimized geometric parameters. This advancement underscores the potential for CFDST in high‐performance applications, suggesting that strategic modifications in ceramsite replacement rate, hollow ratios, and load eccentricities can yield substantial improvements in structural resilience and durability.

Authors

Institutions

Publication Details

Journal
Structural Concrete
Published
2025-04-27
DOI
https://doi.org/10.1002/suco.70057
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on mechanical properties of hollow square steel composite columns embedded steel fiber ceramsite concrete

Qianpeng Nie, Lili Wu, Lei Han, Yonggang Zhang
Structural Concrete
Structural Load-Bearing Analysis
article

Study on mechanical properties of hollow square steel composite columns embedded steel fiber ceramsite concrete

Qianpeng Nie, Lili Wu, Lei Han, Yonggang Zhang
article en

Abstract

Abstract In the evolving landscape of structural engineering, concrete‐filled double skinned tubes (CFDST) attract attention due to their enhanced bearing capacities and deformation capabilities, pivotal for seismic and fire resistance. This study explores the structural behavior and mechanical performance of hollow square steel composite columns embedded with steel fiber‐reinforced ceramsite concrete, in contrast to conventional solid steel tube concrete (CFST) columns with equivalent material composition and external dimensions. The experimental program includes axial and eccentric compression tests on a series of nine CFDST specimens and one CFST specimen. The manipulated parameters include the ceramsite aggregate replacement rate (0%, 50%, 100%), hollow ratio (0, 0.22, 0.42), and eccentricity (0, 30, 50 mm). The documentation of failure modes meticulously highlights shear failure and drum‐like wrinkling in axially loaded specimens at ultimate loads, along with concrete crushing on the compression side accompanied by tension‐side cracking in eccentrically loaded setups. Analysis reveals that the ultimate bearing capacities of CFDST specimens exceed those of their CFST counterparts, with the highest recorded at 1726 kN for axially compressed columns, and decrease progressively with increased hollow ratios and eccentricities. Notably, the study establishes that increasing the ceramsite replacement rate adversely affects the ultimate bearing capacity, illustrating a decrement trend with higher aggregate replacement rates, where the maximum bearing decrease is observed in specimens with a 100% replacement rate, achieving only 1521 kN. The study identifies a significant enhancement in the ductility coefficients of CFDST specimens over traditional CFST designs, underscoring the beneficial integration of steel fibers and optimized geometric parameters. This advancement underscores the potential for CFDST in high‐performance applications, suggesting that strategic modifications in ceramsite replacement rate, hollow ratios, and load eccentricities can yield substantial improvements in structural resilience and durability.

Structural ConcreteVol. 26(5)
China University of Mining and Technology (CN), China Construction Eighth Engineering Division (China) (CN)
Openalex Percentile: Top 91%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.