Arrhythmic Syncope After Aortic Valve Replacement
We present the case of a young man who suffered from severe aortic valve insufficiency and subsequently underwent mechanical aortic prosthesis replacement. One month post-surgery, he presented with syncope and incessant ventricular tachycardia (VT), progressing to cardiogenic shock, which required emergency intra-aortic balloon pump (IABP) support. The VT proved refractory to standard clinical management and demonstrated responsiveness only after IABP support. An electrophysiological study was conducted; however, VT could not be induced during the procedure. Through electrophysiological maneuvers, we suspected bundle branch reentrant ventricular tachycardia (BBR-VT), and successful treatment was achieved via right bundle branch (RBB) ablation.
Authors
- Hugo Cardoso de Souza Falcon (ORCID: https://orcid.org/0000-0001-7136-3448)
- Roberto Carlos Alvarez Coello Coello (ORCID: https://orcid.org/0000-0002-2066-2410)
- Rodrigo Melo Kulchetscki (ORCID: https://orcid.org/0000-0002-9322-5641)
- Muhieddine Omar Chokr (ORCID: https://orcid.org/0000-0001-6697-7074)
- Maurício Scanavacca (ORCID: https://orcid.org/0000-0001-7327-2275)
- Victor Hugo dos Santos Sousa
Institutions
- Universidade de São Paulo (BR)
Publication Details
- Journal
- Pacing and Clinical Electrophysiology
- Published
- 2025-04-26
- DOI
- https://doi.org/10.1111/pace.15192
- Primary Topic
- Cardiac Arrhythmias and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00