Structural design and performance of a steel joint for driven precast concrete energy piles

Geothermal energy piles are deep foundations primarily used to transfer building loads down to competent ground layers, while they can be used as a heating and cooling source/sink for buildings. Most energy pile foundations are cast-in-place piles, while precast concrete driven energy piles (DEPs) have not been utilized due to the lack of a suitable joint to connect pile segments. This study presents a detailed structural design and performance of a novel steel joint for precast concrete DEPs. Firstly, the two most common joint sizes are designed based on the finite element method, and the dimensions and steel grades of the joint are presented. Secondly, the casting procedure of energy piles using the newly designed joint is explained in detail. Thirdly, the impact and bending tests performed according to the standards are presented, the standard procedures are critically evaluated, and recommendations are provided. The impact test results show that both joint sizes remained undamaged after being subjected to 1000 blows, imposing a minimum of 28 MPa of stress. The small and large sizes of joints have a flexural stiffness (EI) of 3500 kN.m 2 and 7720 kN.m 2 , respectively, according to the standard flexural tests. Lastly, the flexural stiffness distribution of the pile and joints is measured using digital image correlation (DIC) and compared with the current method recommended by the standard. The current standard requirements measure flexural stiffness based on point sensor measurements, and the distribution of flexural stiffness along the pile and joint is not evaluated. Standard stiffness is affected by the concrete and reinforcements in the pile; however, there is no standard requirement for the type/grade of the concrete and reinforcements used for manufacturing the test specimens. • Structural design of steel joint for precast concrete driven energy piles. • Casting process of segmental precast concrete driven energy piles. • Standard structural integrity testing of driven energy pile joints. • Impact and bending testing of precast concrete driven energy piles. • Shortcomings of the current standard method, and recommendations for improvement.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-04-26
DOI
https://doi.org/10.1016/j.engstruct.2025.120256
Citations
5
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural design and performance of a steel joint for driven precast concrete energy piles

Jukka Haavisto, Habibollah Sadeghi, Anssi Laaksonen, Rao Martand Singh et al.
5 citations
Engineering Structures
Geothermal Energy Systems and Applications
1.82
article

Structural design and performance of a steel joint for driven precast concrete energy piles

Jukka Haavisto, Habibollah Sadeghi, Anssi Laaksonen, Rao Martand Singh, Teemu Tupala
article en
5 citations

Abstract

Geothermal energy piles are deep foundations primarily used to transfer building loads down to competent ground layers, while they can be used as a heating and cooling source/sink for buildings. Most energy pile foundations are cast-in-place piles, while precast concrete driven energy piles (DEPs) have not been utilized due to the lack of a suitable joint to connect pile segments. This study presents a detailed structural design and performance of a novel steel joint for precast concrete DEPs. Firstly, the two most common joint sizes are designed based on the finite element method, and the dimensions and steel grades of the joint are presented. Secondly, the casting procedure of energy piles using the newly designed joint is explained in detail. Thirdly, the impact and bending tests performed according to the standards are presented, the standard procedures are critically evaluated, and recommendations are provided. The impact test results show that both joint sizes remained undamaged after being subjected to 1000 blows, imposing a minimum of 28 MPa of stress. The small and large sizes of joints have a flexural stiffness (EI) of 3500 kN.m 2 and 7720 kN.m 2 , respectively, according to the standard flexural tests. Lastly, the flexural stiffness distribution of the pile and joints is measured using digital image correlation (DIC) and compared with the current method recommended by the standard. The current standard requirements measure flexural stiffness based on point sensor measurements, and the distribution of flexural stiffness along the pile and joint is not evaluated. Standard stiffness is affected by the concrete and reinforcements in the pile; however, there is no standard requirement for the type/grade of the concrete and reinforcements used for manufacturing the test specimens. • Structural design of steel joint for precast concrete driven energy piles. • Casting process of segmental precast concrete driven energy piles. • Standard structural integrity testing of driven energy pile joints. • Impact and bending testing of precast concrete driven energy piles. • Shortcomings of the current standard method, and recommendations for improvement.

Engineering StructuresVol. 336
Tampere University (FI), Norwegian University of Science and Technology (NO), Valmet Automotive (Finland) (FI)
Openalex Percentile: Top 15%
Geothermal Energy Systems and Applications
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.