Method to identify optical path transmittance by using cat’s-eye retroreflectors

In optical systems used in nuclear fusion reactors, the reflectance of in-vessel mirrors may change due to the deposition of impurities or corrosion. To address this issue, a methodology was proposed whereby ex-vessel light is used to determine the transmittance of an optical system by measuring the light reflected by a retroreflector that is temporarily placed at the tip of the optical system. However, because the reflectance of retroreflectors themselves is not always constant, a reliable method for absolute sensitivity calibration has yet to be established. In this study, we developed a method for measuring the reflectance of a cat’s-eye retroreflector and, consequently, the transmittance of the desired optical system. Developing this method entailed an analysis of the variation in number of reflections and reflection positions within the cat’s-eye retroreflector.

Authors

Institutions

Publication Details

Journal
Optik
Published
2025-04-26
DOI
https://doi.org/10.1016/j.ijleo.2025.172350
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method to identify optical path transmittance by using cat’s-eye retroreflectors

Takanori Kikuchi, Tomohiro Yokozuka, Hiroki Natsume, Sin-iti Kitazawa et al.
Optik
Spectroscopy Techniques in Biomedical and Chemical Research
article

Method to identify optical path transmittance by using cat’s-eye retroreflectors

Takanori Kikuchi, Tomohiro Yokozuka, Hiroki Natsume, Sin-iti Kitazawa, K. Nojiri, Kazuhiro Torimoto, E. Yatsuka, Y. Nunoya
article en

Abstract

In optical systems used in nuclear fusion reactors, the reflectance of in-vessel mirrors may change due to the deposition of impurities or corrosion. To address this issue, a methodology was proposed whereby ex-vessel light is used to determine the transmittance of an optical system by measuring the light reflected by a retroreflector that is temporarily placed at the tip of the optical system. However, because the reflectance of retroreflectors themselves is not always constant, a reliable method for absolute sensitivity calibration has yet to be established. In this study, we developed a method for measuring the reflectance of a cat’s-eye retroreflector and, consequently, the transmittance of the desired optical system. Developing this method entailed an analysis of the variation in number of reflections and reflection positions within the cat’s-eye retroreflector.

OptikVol. 332
Tokai University (JP), National Institutes for Quantum Science and Technology (JP)
Openalex Percentile: Top 93%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.