Marker based and markerless motion capture for equestrian rider kinematic analysis: A comparative study

The study hypothesised that a markerless motion capture system can provide kinematic data comparable to a traditional marker-based system for riders mounted on a horse. The objective was to assess the markerless system's accuracy by directly comparing joint and segment angle measurements taken during walking and trotting with those obtained from a marker-based system. Ten healthy adult participants performed five dynamic trials during walking and trotting. A twelve-camera marker-based system and eight-camera 2D video-based system were synchronised. Three-dimensional hip, knee, shoulder and elbow joint angles, and the global trunk and pelvis angle were computed for comparison between the two systems. To assess the error between systems, the root mean square difference (RMSD) was averaged across each gait cycle and statistical parametric mapping (SPM) paired t-tests were applied. The sagittal trunk angle had the lowest RMSD of 2.0° and elbow rotation had the highest RMSD of 19°, with the same values for walking and trotting. SPM indicated increased hip flexion (0-100 %, p < 0.001) and elbow flexion (24-47 %, p = 0.03; 63-100 %, p < 0.001) in the walking gait cycle for the markerless system. A lack of joint range of motion and obscured medial limbs during walking whilst mounted on horses may cause increased offsets for markerless data in equestrian riders. No significant differences were found for the transverse plane, yet there tended to be increased RMSD. This lack of consistency suggests results from the transverse plane in equestrian riders should be interpreted with caution. Study findings indicate that markerless technology has the potential to be a suitable alternative to marker-based systems for assessment of equestrian riders, dependent on the segment/joint angle of interest and the level of acceptable error. These results indicate that markerless systems can effectively be utilised for rider biofeedback, though their application may be limited for specific joint analyses.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-04-26
DOI
https://doi.org/10.1016/j.jbiomech.2025.112728
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Marker based and markerless motion capture for equestrian rider kinematic analysis: A comparative study

Charlotte Apps, Martin Lewis, Heather Cameron‐Whytock, Hannah Divall
Journal of Biomechanics
Sports Performance and Training
article

Marker based and markerless motion capture for equestrian rider kinematic analysis: A comparative study

Charlotte Apps, Martin Lewis, Heather Cameron‐Whytock, Hannah Divall
article en

Abstract

The study hypothesised that a markerless motion capture system can provide kinematic data comparable to a traditional marker-based system for riders mounted on a horse. The objective was to assess the markerless system's accuracy by directly comparing joint and segment angle measurements taken during walking and trotting with those obtained from a marker-based system. Ten healthy adult participants performed five dynamic trials during walking and trotting. A twelve-camera marker-based system and eight-camera 2D video-based system were synchronised. Three-dimensional hip, knee, shoulder and elbow joint angles, and the global trunk and pelvis angle were computed for comparison between the two systems. To assess the error between systems, the root mean square difference (RMSD) was averaged across each gait cycle and statistical parametric mapping (SPM) paired t-tests were applied. The sagittal trunk angle had the lowest RMSD of 2.0° and elbow rotation had the highest RMSD of 19°, with the same values for walking and trotting. SPM indicated increased hip flexion (0-100 %, p < 0.001) and elbow flexion (24-47 %, p = 0.03; 63-100 %, p < 0.001) in the walking gait cycle for the markerless system. A lack of joint range of motion and obscured medial limbs during walking whilst mounted on horses may cause increased offsets for markerless data in equestrian riders. No significant differences were found for the transverse plane, yet there tended to be increased RMSD. This lack of consistency suggests results from the transverse plane in equestrian riders should be interpreted with caution. Study findings indicate that markerless technology has the potential to be a suitable alternative to marker-based systems for assessment of equestrian riders, dependent on the segment/joint angle of interest and the level of acceptable error. These results indicate that markerless systems can effectively be utilised for rider biofeedback, though their application may be limited for specific joint analyses.

Journal of BiomechanicsVol. 186
University of Lancashire (GB), Comagine Health (US), Clifton Hospital (GB), Nottingham Trent University (GB)
Openalex Percentile: Top 89%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.