Development of a real-time boron imaging method for BNCT using CdTe-DSD at the JRR-3

Boron neutron capture therapy (BNCT) is a neutron-based cancer treatment requiring a real-time <sup>10</sup>B dose monitor to optimize effectiveness. We report using of the cadmium telluride double-sided strip detector (CdTe-DSD), distinguished by its high-energy resolution in full width at half maximum (FWHM) of 7.3 keV at 511 keV and a spatial resolution of 250μm for accurate boron imaging. Employing the CdTe-DSD with a pinhole collimator, our experiment at Japan Research Reactor No. 3 (JRR-3) evaluated the <sup>10</sup>B distribution in a solid sample containing a <sup>10</sup>B concentration of 0.3 mg during neutron exposure. Although measuring the <sup>10</sup>B signal is significantly affected by the background from the γ-rays of <sup>113</sup>Cd, we successfully obtained a circular projection image with a diameter of 11.5 mm, revealing the precise location of <sup>10</sup>B, with a counting rate of 0.115 cps and SNR of approximately 25.7%. The results reveal the CdTe-DSD's capability to enhance BNCT by providing detailed insights into the <sup>10</sup>B distribution within the sample with high fidelity.

Authors

Institutions

Publication Details

Journal
Applied Radiation and Isotopes
Published
2025-04-26
DOI
https://doi.org/10.1016/j.apradiso.2025.111845
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a real-time boron imaging method for BNCT using CdTe-DSD at the JRR-3

Shin׳ichiro Takeda, Tadayuki Takahashi, Takahito Osawa, Kazuhiko Ninomiya et al.
1 citations
Applied Radiation and Isotopes
Nuclear Physics and Applications
1.88
article

Development of a real-time boron imaging method for BNCT using CdTe-DSD at the JRR-3

Shin׳ichiro Takeda, Tadayuki Takahashi, Takahito Osawa, Kazuhiko Ninomiya, Takehiro Sumita, Shin Watanabe, Takahiro Minami, I. Chiu, M. Ikeda
article en
1 citations

Abstract

Boron neutron capture therapy (BNCT) is a neutron-based cancer treatment requiring a real-time <sup>10</sup>B dose monitor to optimize effectiveness. We report using of the cadmium telluride double-sided strip detector (CdTe-DSD), distinguished by its high-energy resolution in full width at half maximum (FWHM) of 7.3 keV at 511 keV and a spatial resolution of 250μm for accurate boron imaging. Employing the CdTe-DSD with a pinhole collimator, our experiment at Japan Research Reactor No. 3 (JRR-3) evaluated the <sup>10</sup>B distribution in a solid sample containing a <sup>10</sup>B concentration of 0.3 mg during neutron exposure. Although measuring the <sup>10</sup>B signal is significantly affected by the background from the γ-rays of <sup>113</sup>Cd, we successfully obtained a circular projection image with a diameter of 11.5 mm, revealing the precise location of <sup>10</sup>B, with a counting rate of 0.115 cps and SNR of approximately 25.7%. The results reveal the CdTe-DSD's capability to enhance BNCT by providing detailed insights into the <sup>10</sup>B distribution within the sample with high fidelity.

Applied Radiation and IsotopesVol. 222
Hiroshima University (JP), Japan Atomic Energy Agency (JP), Kyushu University (JP), Kavli Institute for the Physics and Mathematics of the Universe (JP), Japan Aerospace Exploration Agency (JP), Kavli Institute for the Physics and Mathematics of the Universe (JP), Institute of Space and Astronautical Science (JP), The University of Tokyo (JP)
Iketani Science and Technology Foundation, Japan Society for the Promotion of Science
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Nuclear Physics and Applications
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.