Achieving operational synergy between different adaptive façade technologies

• Multi-functional facades can reduce energy use and enhance occupant comfort. • Development and fabrication of a multi-functional adaptive building façade. • Optimal control methods for multi-functional façade through experiments and simulations. • Investigating energy consumption and occupant comfort under different operational conditions. • Control framework demonstrated improvements in building performance and comfort. Adaptive building facades provide variable shading, thermal insulation, and ventilation. These can be combined in a specific configuration for specific ambient and internal condition to minimise energy used to meet the comfort and well-being of building occupants. Careful design and operation are necessary to ensure that system attributes work together effectively. Control frameworks for adaptive façade systems that optimally vary the contribution of distinct attributes as condition change have not been fully developed. This paper (i) presents the development and fabrication of a multi-functional façade, (ii) explores possible means and challenges of achieving optimal control of an adaptive façade with multiple functionalities and (iii) investigates energy consumption and occupancy comfort through both experiment and simulation. The results showed that the adaptive façade system resulted in 39.5 % heating energy savings, 18.7 % cooling energy savings, and 4.3 % lighting energy savings compared to a conventional façade without adaptive technologies. Daylight comfort was improved by 7.3 %, highlighting the effectiveness of integrating multiple façade functionalities under a unified control framework.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-04-26
DOI
https://doi.org/10.1016/j.rineng.2025.105000
Citations
4
Primary Topic
Structural Engineering and Vibration Analysis
Type
article
Field-Weighted Citation Impact
3.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving operational synergy between different adaptive façade technologies

H. Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O’Sullivan et al.
4 citations
Results in Engineering
Structural Engineering and Vibration Analysis
3.81
article

Achieving operational synergy between different adaptive façade technologies

H. Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O’Sullivan, N O’Neill
article en
4 citations

Abstract

• Multi-functional facades can reduce energy use and enhance occupant comfort. • Development and fabrication of a multi-functional adaptive building façade. • Optimal control methods for multi-functional façade through experiments and simulations. • Investigating energy consumption and occupant comfort under different operational conditions. • Control framework demonstrated improvements in building performance and comfort. Adaptive building facades provide variable shading, thermal insulation, and ventilation. These can be combined in a specific configuration for specific ambient and internal condition to minimise energy used to meet the comfort and well-being of building occupants. Careful design and operation are necessary to ensure that system attributes work together effectively. Control frameworks for adaptive façade systems that optimally vary the contribution of distinct attributes as condition change have not been fully developed. This paper (i) presents the development and fabrication of a multi-functional façade, (ii) explores possible means and challenges of achieving optimal control of an adaptive façade with multiple functionalities and (iii) investigates energy consumption and occupancy comfort through both experiment and simulation. The results showed that the adaptive façade system resulted in 39.5 % heating energy savings, 18.7 % cooling energy savings, and 4.3 % lighting energy savings compared to a conventional façade without adaptive technologies. Daylight comfort was improved by 7.3 %, highlighting the effectiveness of integrating multiple façade functionalities under a unified control framework.

Results in EngineeringVol. 26
Science Foundation Ireland (IE), University College Cork (IE), International Energy Research Centre (IE), Technological University Dublin (IE)
Openalex Percentile: Top 8%
Structural Engineering and Vibration Analysis
3.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines